EasyManua.ls Logo

SFE 95-STD1 - 5 Programming; Basic Programming

SFE 95-STD1
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-PROGRAMMING
5.1 Basic programming
The most common operating parameters are set in the basic menu. To access the basic
menu, press and release the button. The basic menu contains the following
parameters:
Press to switch parameters.
While the parameters are being edited, the regeneration icon is on and flashing.
DATA DESCRIPTION DEFAULT MIN - MAX
12
:
H
24
:
H
Hour format setting as 12 or 24 hours. Press or to
edit this parameter.
Current time. The current time is displayed flashing, together
with the day of the week, fixed. Press or to edit.
24H
12H – 24H
00
:
00
00:00 00:00
23:59
Day of week. The current day is displayed flashing, together
with the current time, fixed. Press or to edit.
00
:
00
Mo N.A.
Days enabled for regeneration. The display shows “dx y”
where x is the day of the week (1-7) and y shows whether the
selected day is enabled for regeneration “1” or not, “0”. For
every enabled day, the top of the display shows the relevant
flashing icon.
Press to edit the setting of the selected day (x),
press to enable or disable the selected day (y).
1
:
1
All enabled N.A.
Regeneration time. Regeneration start time when a delayed
time or cubic metre start is enabled. Press or to edit.
2:00 00:00
23:59
2
:
00
End of the programming.
N.A. N.A.
E
n d
:
28