30
SFE
DATA DESCRIPTION DEFAULT MIN - MAX
00
:
Duration of the second regeneration cycle stop (minutes).
Press or to edit. If the parameter is set to off, the
stop will be skipped and the system will directly go to the
next stop.
30 Of-99
3C 00
:
Duration of the third regeneration cycle stop (minutes).
Press or to edit. If the parameter is set to off, the
stop will be skipped and the system will directly go to the
next stop.
5 Of-99
00
:
Duration of the fourth regeneration cycle stop (minutes).
Press or to edit. If the parameter is set to off, the
stop will be skipped and the system will directly go to the
next stop.
5 Of-99
5A00
:
Number of regenerations before a salt alarm is generated.
Press or to edit.
NOTE: See note 1 to calculate the number of regenerations
before a salt alarm is generated.
10 00-99
00
:
Days of interval for the mandatory regeneration. Press
or to edit. If this parameter is set to Of, the function
is disabled.
NOTE: This type of regeneration is carried out at the
regeneration time even on non enabled days.
14 Of-14
FR 00
:
Frequency of the mains 50 or 60 Hz. Press or to edit.
50 50-60
FC 00
:
Duration of the cycle end pulse, this parameter can take
values from 1 to 99 minutes or have the wording FCCL to
indicate that the board is set to the chlorine function. Press
or to edit.
FCCL CL-99
S00
:
Interval time between regenerations. Press or to
edit. This parameter is displayed after the start up mode only
if an interval start has been selected (SH-03).
1 1-12
E
n d
:
End of the programming N.A. N.A.
Press to switch parameters.
While the parameters are being edited, the regeneration icon is on and flashing.