26
AF-T908X
AF-R908X
AF-R1108X
AF-R1208X
Symptom Check Defect Remedy
Fan motor doesn't
operate with
"Selector switch" set
at "Fan only"
1) Check PWB 
connector CN1
1) Connector open CN1
1) Joint of connector CN1
3) Check
a. Current exceeds
rated one
b. Motor lead wire
2) Check 
a. Fan capacitor
b. Power cord
c. Fan motor
4) Check fan motor
circuit
Fan motor operates
but supplies no air
when "Selector 
switch" set at 
"Fan only"
1) Check motor
rotating direction
2) Check if air is
delivered
2) Crack at solder part of CN1
1) Fan capacitor defective
2) Power supply voltage is too low
3) Fan motor defective
1) Fan motor breaking locked
1) Fan motor coil shorted
1) Motor lead wire burn out
2) Over solder
1) Change capacitor
2) Improve power supply
equipment
3) Change fan motor
1) Change fan motor
2) Change repair lead wire
1) Change fan motor
1) Change repair lead wire
2) Fan motor lead wire burn out
1) Dirty air filter
2) Fan screw or nut loose and only
motor rotating
1) Clean
2) Tighten up
Compressor starts
but stops soon
1) Check air filter
and fan elements
4) Rated current is
normal but
overload relay or
internal thermostat
cuts out
1) Voltage is low and over-current
runs, overload relay or internal
thermostat operates
2) Wiring for power supply 
equipment too thin
1) Overload relay or internal
thermostat operates as fan is
not rotating
2) Overload relay or internal
thermostat operates as fan 
nut is loose
1) Overload relay or internal
thermostat operates as outdoor
air temp. is too high
Overload relay or internal 
thermostat defective
1) Improve the equipment
2) Improve the equipment
1) Change switch
check electric circuit
(fan)
2) Tighten up
1) Ventilate well for outdoor
exchanger, avoid sun
light, remove heat source
from around outdoor unit
Change overload relay or
compressor
3) Check the temp.
of air at condensor
2) Improper ventilation for outdoor
heat exchanger.
Overload relay or internal
thermostat operates as the temp.
of outdoor unit is too high
2) Clean the outdoor unit
Improve ventilation for
outlet port of outdoor
exchanger
1) Measure power
supply voltage
2) Motor rotating wrong
2) Change fan motor