EasyManua.ls Logo

Sharp AH-S22DP2 - Refrigeration Cycle

Sharp AH-S22DP2
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
AH-S22DP2
AH-S25DP2
AH-S32DP2
1
2
Capillary tube
3
Outdoor unit
Condenser
Evaporator
Indoor unit
Compressor
Flare coupling Flare coupling
Silencer
4
3-way
valve
2-way
valve
Accumulator
Indoor side
Standard conditions:
AH-S22DP2/S25DP2/S32DP2
Dry-bulb Temp. (˚C) Relative Humidity (%)
27Cooling 47
Outdoor side
Dry-bulb Temp. (˚C) Relative Humidity (%)
35 40
Temperature at each part and pressure in 3-way valve
Operation
mode
Model
Cool
(Max.)
1
2
3
4
3-way valve
pressure
(MPaG)
85˚C
40˚C
12˚C
5˚C
0.44
89
95˚C
38˚C
12˚C
8˚C
0.45
101
83˚C
42˚C
14˚C
5˚C
0.46
97
68˚C
40˚C
13˚C
7˚C
0.55
60 settle
68˚C
42˚C
15˚C
9˚C
0.60
60 settle
Cool
Cool
(Max.)
Cool
Cool
(Max.)
Cool
68˚C
41˚C
14˚C
8˚C
0.63
60 settle
No.
Hz
Dimension of Capillary tube
AH-S22DP2
AH-S25DP2
AH-S32DP2
Model
ø2.7
ø2.7 ø2.7
O.D
ø1.5 ø1.5
ø1.6
600
600
I.D L
O.D
I.D L
O.D
I.D L
300
Capillary tube
AH-S25DP2AH-S22DP2 AH-S32DP2
REFRIGERATION CYCLE
Figure R-1. Refrigeration Cycle