Main Sub
Item Content
Adjustment
code code range
17 Clears PF
trouble.
SIMULATION NO.17
PF TROUBLE CANCELLATION
PRINT SWITCH: EXECUTE SIMULATION
[Content] The PF trouble is cleared. After the execution, the simulation is cleared.
(a) Operation/display
[PRINT]: The simulation is executed and the screen displays the main code input
mode.
[PAUSE]: The execution of the simulation is stopped and the screen returns to the
main code input screen.
[CA]: The execution of the simulation is stopped and the simulation is terminated.
20 Clears
maintenance
counter.
SIMULATION NO.20
MAINTENANCE COUNTER
WOULD YOU MIND IF CLEARING EXECUTE?
1. EXECUTE 2. CANCEL
SELECT WITH TEN KEY
• [1] key
SIMULATION NO.20
MAINTENANCE COUNTER
COMPLETED CLEARING
MAINTENANCE COUNTER DISPLAY
MAINTENANCE: 000,000
[PAUSE]KEY: END DISPLAY
[Content] The maintenance counter is cleared and then the maintenance counter is dis-
played.
(a) Operation/display
[1]: The simulation is executed and the screen changes to the maintenance
counter mode.
[2]: The execution of the simulation is stopped and the screen returns to the
main code input screen. If any key other than [1] or [2] is pressed, the error
buzzer sounds.
[PAUSE]: The execution of the simulation is stopped and the screen returns to the
main code input screen.
[CA]: The execution of the simulation is stopped and the simulation is terminated.
9 – 30