Item Content
Adjustment
code code range
22 15 Displays trouble
counter.
SIMULATION NO.22-15
TROUBLE COUNTER DISPLAY
TROUBLE COUNTER: XXX,XXX
TROUBLE MEMORY DISPLAY
XX-XX, XX-XX, XX-XX, XX-XX, XX-XX
XX-XX, XX-XX, XX-XX, XX-XX, XX-XX
XX-XX, XX-XX, XX-XX, XX-XX, XX-XX
XX-XX, XX-XX, XX-XX, XX-XX, XX-XX
[PAUSE]KEY: END DISPLAY
[Content] The current value of the total trouble counter and 20 trouble codes which have
occurred recently are displayed, starting with the trouble code which has occurred
most recently.
(Main code) – (Sub code)
If the number of troubles which have occurred is less than 20, “-” is substituted for
the blank.
(a) Operation/display
[PAUSE]: The execution of the simulation is stopped and the screen returns to the
sub code input screen.
[CA]: The execution of the simulation is stopped and the simulation is terminated.
16 Displays copy
counter.
SIMULATION NO.22-16
COPY COUNTER DISPLAY
COPY COUNTER: XXX,XXX
[PAUSE]KEY: END DISPLAY
[Content] The current value of the copy counter is displayed.
(a) Operation/display
[PAUSE]: The execution of the simulation is stopped and the screen returns to the
sub code input screen.
[CA]: The execution of the simulation is stopped and the simulation is terminated.
17 Displays
PDA/ZR print
counter.
SIMULATION NO.22-17
PDA/ZR PRINT COUNTER DISPLAY
PDA/ZR PRINT COUNTER: XXX,XXX
[PAUSE]KEY: END DISPLAY
[Content] The current value of the PDA/ZR print counter is displayed.
(a) Operation/display
[PAUSE]: The execution of the simulation is stopped and the screen returns to the
sub code input screen.
[CA]: The execution of the simulation is stopped and the simulation is terminated.