Main Sub
Item Content
Adjustment
code code range
26 15 Sets fusing curl
correction mode.
0-1SIMULATION NO.26-15
FUSING CURL MODE SETTING [X] :_
0. NORMAL MODE
1. FUSING CURL MODE
INPUT SETUP VALUE AND PRESS PRINT SW
[Content] The fusing curl correction mode can be set. If this mode is set, the driving unit
rotates at all times during warming-up. The current setting is displayed and a new
setting can be entered.
(a) Operation/display
[PRINT]: If the entered value is valid, the current setting is updated and the sub code
input screen is displayed. If the entered value is not valid, the input field is
cleared and the error buzzer sounds. If any value is not entered, the setting
remains unchanged and the sub code input screen is displayed.
[0-1]: Enters new settings
[C]: Clears the input field.
[PAUSE]: No setting is made and the sub code input screen is displayed.
[CA]: The execution of the simulation is stopped and the simulation is terminated.
18 Sets toner save
mode.
1-2SIMULATION NO.26-18
TONER SAVE MODE SETTING [X] :_
1. ON 2. OFF
INPUT SETUP VALUE AND PRESS PRINT SW
[Content] The toner save mode can be set. The current setting is displayed and a new
setting can be entered.
(a) Operation/display
[PRINT]: If the entered value is valid, the current setting is updated and the sub code
input screen is displayed. If the entered value is not valid, the input field is
cleared and the error buzzer sounds. If any value is not entered, the setting
remains unchanged and the sub code input screen is displayed.
[1-2]: Enters new settings
[C]: Clears the input field.
[PAUSE]: No setting is made and the sub code input screen is displayed.
[CA]: The execution of the simulation is stopped and the simulation is terminated.
9 – 49