(2) Copy lamp
1 Remove the right and left document guides and remove the table
glass.
2 Displace the copy lamp unit to the notched part at the rear of the
upper cabinet.
3 Remove the copy lamp.
Note: When reinstalling the copy lamp, use caution not to have the
wrong direction.
The copy lamp should be reinstalled as shown above, so that
the copy lamp projection is located close to the R side.
(3) 2nd and 3rd mirror base unit
1 Remove the right and left document guides and remove the table
glass.
2 Remove the mirror base wire from the 2nd and 3rd mirror base
unit.
3 Move the 2nd and 3rd mirror base unit to the square hole in the
optical base and twist it to remove.
How to stretch the mirror base wire
(Check the following in advance.)
Check the wire winding pulley stopping position.
Check the wire winding pulleys (front/rear) have a wire groove in the
same position.
(Visual checks)
If the two wire grooves are much different in their level, loosen two set
screws securing the pulleys and align the position of the two wire
winding pulleys (front/rear).
Tighten the two set screws securing the pulleys.
1 Hook the mirror base wire holder on the optical base hook.
2 Apply the mirror base B against the mirror base positioning plate.
Pass the front and rear mirror base wires through the outside
grooves in the mirror base B pulley.
3 Pass the mirror base wires through the grooves in the paper feed
pulley.
4 Pass the mirror base wires under the mirror base B and wind them
on the winding pulleys.
At this time, secure the wire groove of each winding pulley at its
upper position. Wind the mirror base wires 9 turns, with the 8th
wind settled into the groove.
The 1st wind of the mirror base wires should be 9 10 mm away
from the pulley groove toward the frame side.
5 Pass the mirror base wires through the groove in the paper exit
pulley.
6 Pass the mirror base wires through the inner groove in the mirror
base B pulley.
7 Pass the mirror base wire through the wire guide.
8 Hook the mirror base wire tension spring on the slot in the optical
base.
F
R
(Rear) (Front)
7 – 12