[8] ADJUSTMENT
No. Item Contents Simulation
1 Developing
section
(1) Adjusting developing doctor clearance
(2) Adjusting developing magnet roller main pole position
(3) Adjusting DV bias voltage 8-01
(4) Pay attention to the following points when installing
developing unit rollers
(5) Pay attention to the following points when attaching front
and rear developing side seals.
2 Process section (1) Adjusting high voltage output and balance A Using special measurement tools
B Adjusting transfer charger current 8-06
C Adjusting main charger grid voltage 8-02
D Adjusting separation charger output 8-07
(2) Precautions in maintaining high-voltage charger unit A Main charger unit
B Transfer/separation charger unit
3 Laser unit (1) Checking printing by laser unit
(adjusting distortion by self-printing mode)
64-01
4 Optical section (1) Adjusting magnification in main-scanning direction
(2) Adjusting magnification in sub-scanning direction 48-02
(3) Adjusting distortion in longitudinal direction
(4) Adjusting distortion in lateral direction
(5) Adjusting leading edge position of copy 50-01, 50-02
5 Document
detection section
(1) Adjusting document detection arm unit 41-01
(2) Adjusting document detection level 41-02, 41-03
6 Others (1) Printing off-center 50-10, 50-11
(2) Adjusting document off-center A Document table 50-12
7 Paper tray 1/2 (1) Adjust any center misalignment
8 Paper tray 3 (1) Adjust any center misalignment
9 ADU (1) Adjust any matching guide 52-01
(2) Adjust any center misalignment
10 RADF (1) Adjust any center misalignment
(2) Document lead edge position adjustment 53
1. Developing section
(1) Adjusting developing doctor clearance
1 Remove the four screws securing the toner hopper and the
developer tank and 5-pin connector, to separate the toner tank
hopper from the developer tank.
2 Loosen the four screws A securing the DV doctor (2 at the front
and 2 at the rear frame).
3 Insert 0.05 mm clearance gauges at positions 50 80 mm from
the end of the DV doctor.
4 Press the DV doctor in the direction indicated by the arrow, and
tighten the DV doctor fixing screws (4 screws both at the front and
rear frames).
5 Make sure the clearance is 0.55+0.03-0.03 at the positions 50
80 mm from both ends of the DV doctors.
* Note: Use caution not to damage the DV doctor or MG roller
when inserting clearance gauges.
0.55
0.03
0.03
A A
50mm
50mm
30mm
30mm
8 – 1