Loading...
AR-6020V SIMULATIONS 6-19
44
10 Process control data display 2
When this simulation is executed, the current code number is displayed on the number of copies display.
Switching can be made with [Copy ratio] keys.
When the negative value is displayed, the [Developer replacement required] indicator lights.
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
11 Process control data display 3
When this simulation is executed, the current code number is displayed on the number of copies display.
Switching can be made with [Copy ratio] keys.
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
12 Process control data display 4
When this simulation is executed, the current code number is displayed on the number of copies display.
Switching can be made with [Copy ratio] keys.
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
Main
code
Sub
code
Contents Details of operation
No. Contents Setting Display Range Default
1 Laser power default value (CP) (TSOFF) - O 0 - 255 112
2 Laser power default value (PRT) (TSOFF) - O 0 - 255 112
3 Corrected laser power default value (CP) (TSOFF) - O 0 - 255 112
4 Corrected laser power default value (PRT) (TSOFF) - O 0 - 255 112
5 Laser power default value (CP) (TSON) - O 0 - 255 112
6 Laser power default value (PRT) (TSON) - O 0 - 255 112
7 Corrected laser power default value (CP) (TSON) - O 0 - 255 112
8 Corrected laser power default value (PRT) (TSON) - O 0 - 255 112
9 Dissolution laser power correction value (CP) - O -127 - 127 0
10 Dissolution laser power correction value (PRT) - O -127 - 127 0
11 Environmental laser power correction value (CP) - O -127 - 127 0
12 Environmental laser power correction value (PRT) - O -127 - 127 0
No. Contents Setting Display Range Default
1 Temperature/humidity area for toner control - O 1 - 8 8
2 Temperature AD value for toner control - O 0 - 1023 466
3 Humidity AD value for toner control - O 0 - 1023 7
4 Temperature AD value for transfer printing - O 0 - 1023 0
5 Humidity AD value for transfer printing - O 0 - 1023 0
6 Temperature/humidity area for transfer printing - O 1 - 8 8
No. Contents Setting Display Range Default
1 Dissolution drum travel distance area - O 1 - 15 0
2 Developer life area for process unit - O 0 - 15 0
3 Environmental correction area - O 1 - 8 8
4 Duplex printing counter - O 0 - 300 8
5 Laser power area - O 0 - 15 0
6 Laser power environmental area - O 0 - 8 7
8 Machine model type - O 0 - 1 0