AR-M355N/M455N MAINTENANCE AND DETAILS OF EACH SECTION 7 - 70
3) Remove the screw, and remove the right noise cover.
4) Remove the connector, and remove the screw.
5) Remove the screw, and remove the rear cabinet.
6) Remove the connector, the screw, and the angle. Remove the
snap band.
7) Remove the power unit.
a-1. Reactor PWB (200V only)
1) Remove the power unit.
2) Remove the connector and the PWB supporter, and remove
the filter PWB.
a-2. Power PWB
1) Remove the power unit.
2) Remove the connector, the screw, and the PWB supporter,
and remove the power PWB.