GB-5
ENGLISH
1
Press the MODE button to select the
operation mode.
AUTO HEAT COOL DRY
2
Press the ON/OFF button to start
operation.
The red OPERATION lamp ( ) on the unit
will light.
3
Press the THERMOSTAT button to set
the desired temperature.
AUTO/DRY MODE
The temperature can be changed up to 2°C
above or below the temperature automatically
determined by the air conditioner.
COOL/HEAT MODE
The temperature can be set within the
range of 18 to 32°C.
4
Press the FAN button to set the desired
fan speed.
AUTO SOFT LOW HIGH
In the DRY mode, the fan speed is preset to
AUTO and cannot be changed.
5
To turn off the unit, press the ON/OFF
button again.
The red OPERATION lamp ( ) on the unit
will turn off.
BASIC OPERATION
TIPS ABOUT AUTO MODE
In the AUTO mode, the temperature setting
and mode are automatically selected accord-
ing to the room temperature when the unit is
turned on.
Modes and Temperature Settings
Room temp.
at operation
start-up
Automatic Operation
Mode
Temperature Setting
Below 21˚C
HEAT
23
˚C
21˚C-24˚C
DRY
Room Temp.
-
2
˚C
24˚C-26˚C
COOL
24˚C
26˚C-28˚C
COOL
25˚C
Above 28˚C
COOL
26˚C
2
5
3
1
4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp AY-AP9KR and is the answer not in the manual?

Sharp AY-AP9KR Specifications

General IconGeneral
TypeSplit system
Multi-splitYes
Product colorWhite
Hose length (max)10 m
Refrigerating mediumR410A
Air conditioner functionsCooling, Heating
Cooling capacity in watts (nominal)820 W
Cooling energy efficiency (EER, W/W)3.22
Heating energy efficiency (COP, W/W)3.63
Seasonal efficiency rating (cooling) (SEER)-
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)800 W
AC input voltage220-240 V
AC input frequency50 Hz
Design load (cooling)- kW
Energy efficiency class (cooling)A
Annual energy consumption (cooling)410 kWh
Hourly energy consumption (cooling)3.7 kWh
Hourly energy consumption (heating)3.6 kWh
Annual energy consumption (heating) (Warmer heating season)- kWh
Indoor unit typeWall-mountable
Indoor unit depth198 mm
Indoor unit width860 mm
Indoor unit height292 mm
Indoor unit weight8500 g
Indoor units quantity1
Indoor unit noise level (high speed)54 dB
Outdoor unit depth250 mm
Outdoor unit width730 mm
Outdoor unit height540 mm
Outdoor unit weight27000 g
Outdoor unit noise level59 dB