EasyManua.ls Logo

Sharp CD-K491W - Service Adjustments; Mechanism Section Adjustments; Tuner Section Adjustments

Sharp CD-K491W
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CD-K491W
– 12 –
MECHANISM SECTION
Driving Force Check
Torque Meter
Specified Value
Play: TW-2412 Tape 1: Over 80 g
Tape 2: Over 80 g
Torque Check
Torque Meter
Tape 2
Play: TW-2111 30 to 60 g. cm 30 to 100 g.cm
Fast forward: TW-2231 50 to 100 g.cm
Rewind: TW-2231 50 to 100 g.cm
Specified
Value
Adjusting
Point
Instrument
Connection
Test Tape
Normal MTT-111 VRM01 3,000 ± Speaker
speed 30 Hz terminal
(Load
resistance:
8 ohms)
ADJUSTMENT
Specified Value
Tape 1
Tape Speed
Figure 12
VRM01
TAPE
SPEED
FAS
SW
TAPE MECHANISM PWB
IF 450 kHz 1,602 kHz T351 *1
MW Band 531 kHz (fL): T306 *2
Coverage 1.1 ± 0.1 V
SW1 Band 3.2 MHz (fL): T307 *2
Coverage 2.0 ± 0.1V
SW1 Band 7.3 MHz (fH): TC305 *2
Coverage 7.7 ± 0.2 V
SW2 Band 9.5 MHz (fL): T308 *2
Coverage 2.1 ± 0.1V
SW2 Band 21.85 MHz (fH): TC304 *2
Coverage 7.7 ± 0.2V
MW 990 kHz 990 kHz T302 *1
Tracking
SW1 3.9 MHz 3.9 MHz (fL): T303 *1
Tracking
SW1 7.1 MHz 7.1 MHz (fH): TC303 *1
Tracking
SW2 11.65 MHz 11.65 MHz (fL): T304 *1
Tracking
SW2 21.45 MHz 21.45 MHz (fH): TC302 *1
Tracking
TUNER SECTION
fL: Low-range frequency
fH: High-renge frequency
• AM IF/RF
Signal generator: 400 Hz, 30%, AM modulated
Test Stage
Instrument
Connection
Frequency
Frequency
Display
Setting/
Adjusting
Parts
*1. Input: Antenna, Output: TP302
*2. Input: Anetnna, Output: TP301

Related product manuals