E-9
Select the length of time you want. The unit automatically 
stops once the selected time is reached.
Select the length of time you want. The unit automatically 
starts once the selected time is passes.
(with the unit OFF)
(with the unit ON)
2hour
10hour
6hour
14hour
4hour
12hour
8hour
CANCELLATION
2hour1hour 4hour 8hour
CANCELLATION
ON TIMER OFF TIMER
PATROLLING FUNCTION
The sensor detects a state requiring attention to room temperature and humidity during operation and tells it with 
Patrolling Light. Both "Dry and Low temperature patrolling" and "High temperature and High humidity patrolling" 
work. (This function informs a room condition. The unit cannot adjust temperature or lower humidity)
It tells that the room is dry or the room temperature is low.  
When Patrolling Light turns to red, the unit operates with airow a little stronger during Intelligent mode (Auto mode).
Material source: Dr. Makoto Shoji, Director of Shoji internal medicine and pediatrics clinic 
in Sendai City, Miyagi Prefecture, Japan
Right gure Absolute humidity
*1
Virus environment Survival rate
*2
(1) Over 11 g
Environment which is less suitable for 
viruses to survive
0 % to small percent
(2) 11 g or less Environment where viruses can survive 5 %
(3) 7 g or less
Environment which is suitable for 
viruses to survive
20 %
•  It does not notify of the existence of viruses themselves.
•  Patrolling Light's illuminating "Green" does not assure 
prevention of infection. Use it as a reference to make an 
environment to prevent infection during typical daily life.
•  While adjusting humidity to approximately 55 % to 65 %  
during operation in Intelligent mode (Auto mode), the 
unit controls humidication, but does not make changes 
according to the virus' environment.
*1  The absolute humidity is the total mass of water vapor present in 1 
m
3
 of air regardless of 
temperature and is expressed in g. While humidity generally used for a weather forecast is called 
relative humidity, which is the ratio of the partial pressure of water vapor to the equilibrium vapor 
pressure of water at a given temperature and is expressed in %. Therefore, the absolute humidity is 
approximately 8 g at 15 
o
C
 and 18 g at 30 
o
C
 even at the same relative humidity of 60 %.
*2 Survival rate of viruses emitted in air after 6 hours under each environment.
Patrolling 
Light
If the beeping sound is set to "ON". (Ref. E-12)
Indoor environment
Temperature 
and humidity 
area (Figure 
below)
Humidity / Temperature 
Monitor 
(for 30 seconds)
Beeping sound
Red
"%" Light turns on
Beep (once)
Dry
(3)
"
o
C" Light ashing
Beep (once)
Low temperature
Green (Normal)
None
Not dry or low 
temperature
(1)·(2)
DRY AND LOW TEMPERATURE PATROLLING
NOTE
When the room is dry and the room temperature is low, viruses survive more easily. We recommend 
that you increase humidity with humidication setting and temperature using heating appliances 
according to your room environment.
          
         
Temperature
(
o
C)
Relative humidity (%)
KC-G60_50_40EU_EN.indd   9 2017/07/28   13:15:56