EasyManua.ls Logo

Sharp KC-G60EU - Selecting Display; Plasmacluster Ion On;Off; Patrolling Function

Sharp KC-G60EU
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
E-10
Humidity Temperature Wattage
OFFON
When the Plasmacluster function is ON, the Plasmacluster
Ion light on the Front Display is on. (Ref.E-6)
SELECTING DISPLAY
PLASMACLUSTER ION ON/OFF
more
3 sec.
more
3 sec.
(with the unit ON)
PATROLLING FUNCTION
The beeping sound of Patrolling Function is set to "Off" at the default. You can change it to "On" or "Cancel
Patrolling Function". (Ref. E-11, E-12)
It tells high temperature and high humidity. When Patrolling Light turns to orange or red, the unit stops humidication
automatically. (However, it is in MAX/MED/LOW mode, it does not stop humidication)
We recommend that you drink some water or lower the room temperature.
Guideline for preventing heatstroke in daily life <Source: website of Japanese Society of Biometeorology>
Temperature
standard
Overview of life
activities to be noted
Precautions
D Danger
Risks that could occur
in all life activities
Elderly people are highly likely to suffer from
heartstroke even in a resting state. Avoid going out
and move to a cooler room.
C
Heavy alert
Avoid blazing sun when going out and pay attention
to an increase of room temperature when staying in
a room.
B Alert
Risks that could occur
in middle level or higher
life activities
Rest regularly when doing exercise or intense work.
A Caution
Risks that could occur
in hard life activities
Generally the risk is low, but people may suffer
when doing hard exercise or hard work.
This is not a function to prevent heatstroke. Please use this function as an assistance.








































               

               

$
%
&
'
Relative humidity (%)
Temperature
(
o
C)
HIGH TEMPERATURE AND HIGH HUMIDITY PATROLLING
NOTE
Patrolling
Light
If the beeping sound is set to "ON". (Ref. E-12)
Indoor environment
Temperature
and humidity
area (Figure
below)
Humidity / Temperature
Monitor
(for 30 seconds)
Beeping sound
Red(Flashing) "
o
C" Light ashing
Beep
・・・
(for 30 seconds)
High temperature
and high humidity
D
Red "
o
C" Light turns on
Beep
・・・
(for 30 seconds)
C
Orange "
o
C" Light turns on
None
Relatively high
temperature and high
humidity
B
Green (Normal)
None
Not high temperature
nor high humidity
A
KC-G60_50_40EU_EN.indd 10 2017/07/28 13:15:58