Is the power cord properly connected?
no
Connect the power cord
v yes
Is the LED (power - H012) lit?
no
Is a voltage of 3v3 measured at X090-1?
(3V3_STB)
no
Replace PSU module
v yes
Is a voltage of 3v3 measured at X013-1?
no
Replace Mainboard
v yes
Is a voltage of over 3v measured at X013-5?
no
Replace Mainboard
v yes
Replace IR PCB
v yes
Power on the set by using the remote. Does it start?
no
Press the power-button on the set. Does it start?
no
Check/replace Mainboard
v yes
Replace IR PCB