60
LC-32LE63x
LC-40LE63x
LC-46LE63x
900 kHz for 12 V to 3.3 V and 12 V to 5 V DC-DC 
converters. The DVB-S2 supply 24 V to 5 V and 24 V to +V 
LNB DC-DC converters operates at 300 kHz while for 5 V 
to 1.1 V DC-DC converter 900 kHz is used.
5.8.6 Exit “Factory Mode”
When an “F” is displayed in the screen’s right corner, this 
means the set is in “Factory” mode, and it normally
happens after a new SSB is mounted. To exit this mode, push 
the “VOLUME minus” button on the TV’s local keyboard for 10 
seconds (this disables the continuous mode).
Then push the “SOURCE” button for 10 seconds until the “F” 
disappears from the screen.
Uart loggings reporting fault conditions, error messages, error 
codes, fatal errors:
• Failure messages should be checked and investigated.For 
instance fatal error on the PNX51x0: check startup of the 
back-end processor, supplies..reset, I
2
C bus. => error 
mentioned in the logging as: *51x0 failed to start by itself*.
• Some failures are indicated by error codes in the logging, 
check with error codes table (see Table “5-2 Error code 
overview”).e.g. => <<<ERROR>>>PLFPOW_MERR.C : 
First Error (id=10,Layer_1=2,Layer_2=23).
• I
2
C bus error mentioned as e.g.: “ I
2
C bus 4 blocked”.
• Not all failures or error messages should be interpreted as 
fault.For instance root cause can be due to wrong option 
codes settings => e.g. “DVBS2Suppoprted : False/True.
In the Uart log startup script we can observe and check the 
enabled loaded option codes.
 
Defective sectors (bad blocks) in the Nand Flash can also be 
reported in the logging.
Startup in the SW upgrade application and observe the Uart 
logging:
Starting up the TV set in the Manual Software Upgrade mode 
will show access to USB, meant to copy software content from 
USB to the DRAM.Progress is shown in the logging as follows: 
“cosupgstdcmds_mcmdwritepart: Programming 102400 bytes, 
40505344 of 40607744 bytes programmed”.
Startup in Jett Mode:
Check Uart logging in Jet mode mentioned as : “JETT UART 
READY”.
Uart logging changing preset:
=> COMMAND: calling DFB source = RC6, system=0, key = 4”.
5.8.9 Loudspeakers
Make sure that the volume is set to minimum during 
disconnecting the speakers in the ON-state of the TV. The 
audio amplifier can be damaged by disconnecting the speakers 
during ON-state of the set!
5.8.10 PSL
In case of no picture when CSM (test pattern) is activated and 
backlight doesn’t light up, it’s recommended first to check the 
inverter on the PSL + wiring (LAYER 2 error = 17 is displayed 
in SDM).
5.8.11 Tuner
Attention: In case the tuner is replaced, always check the tuner 
options!
5.8.12 Display option code
Attention: In case the SSB is replaced, always check the 
display option code in SAM, even when picture is available. 
Performance with the incorrect display option code can lead to 
unwanted side-effects for certain conditions.
After start-up of the Hyperterminal, fill in a name (f.i. “logging”) 
in the “Connection Description” box, then apply the following 
settings: 
1. COMx
2. Bits per second = 115200
3. Data bits = 8
4. Parity = none
5. Stop bits = 1
6. Flow control = none
During the start-up of the TV set, the logging will be displayed. 
This is also the case during rebooting of the TV set (the same 
logging appears time after time). Also available in the logging 
is the “Display Option Code” (useful when there is no picture), 
look for item “DisplayRawNumber” in the beginning of the 
logging. Tip: when there is no picture available during rebooting 
you are able to check for “error devices” in the logging (LAYER 
2 error) which can be very helpful to determine the failure cause 
of the reboot. For protection state, there is no logging.
5.8.8 Guidelines Uart logging
Description possible cases: 
 
Uart loggings are displayed:
• When Uart loggings are coming out, the first conclusion we 
can make is that the TV set is starting up and 
communication with the flash RAM seems to be supported. 
The PNX855xx is able to read and write in the DRAMs.
• We can not yet conclude : Flash RAM and DRAMs are fully 
operational/reliable.There still can be errors in the data 
transfers, DRAM erros, read/write speed and timing 
control.
 
No Uart logging at all:
• In case there is no Uart logging coming out, check if the 
startup script can be send over the I
2
C bus (3 trials to 
startup) + power supplies are switched on and stable.
• No startup will end up in a blinking LED status : error 
LAYER 1 = “2”, error LAYER 2 = “53” (startup with SDM 
solder paths short).
• Error LAYER 2 = “15” (hardware cause) is more related to 
a supply issue while error LAYER 2 = “53” (software cause) 
refers more to boot issues.
 
Service Modes, Error Codes, and Fault Finding (continued)
5.8.7     Logging
  When something is wrong with the TV set (f.i. the set is reboot-
ing) you can check for more information via the logging in Hy-
perterminal. The Hyperterminal is available in every Windows 
application via Programs, Accessories, Communications, Hy-
perterminal.