EasyManua.ls Logo

Sharp LC-70UD1U - Page 32

Sharp LC-70UD1U
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LC-70UD1U
5 – 13
9. White balance adjustment
9.1. White balance adjustment (For details about the adjustment procedure, refer to “Kameyama Model Integrated Monitor
WB Adjustment Specification V1.92”.)
Adjustment
point
Adjustment conditions Adjustment procedure
1 Setting 1) Set the unit to the following conditions.
AV MODE: [DYNAMIC]
Backlight: +16
Active Backlight: OFF
Aging Time: Min. 60 minutes
2) Connect the unit with the white balance adjustment jig.
2 Automatic
adjustment exe-
cution
[DYNAMIC]
Adjustment
[Command]
Process mode
KRSW0001
KKT10037
Setting
KY0F0000
0SDS0001
SBSL0016
Multi-point adjustment mode
MSET0001
Point 7
LEV70121
MG7G****
MG7B****
MG7R****
Point 6
LEV60098
MG6G****
MG6B****
MG6R****
Point 5
LEV50073
MG5G****
MG5B****
MG5R****
Point 4
LEV40046
MG4G****
MG4B****
[Adjustment procedure]
1) Send the “adjustment process” code using the remote control.
[DYAMIC]Adjustment
2) Specify the strongest color as the fixed color, and adjust the RGB by the MG7*****
command so that it becomes the standard value through negative adjustment.
3) Set the point 6 to the specified gradation, set the G correction value (3136 x G value
of point 7/3872) (fractions rounded off) and adjust the RB so that it becomes the stan-
dard value.
4) Set the point 5 to the specified gradation, set the G correction value (2336 x G value
of point 7/3872) (fractions rounded off) and adjust the RB so that it becomes the stan-
dard value.
5) Set the point 4 to the specified gradation, set the G correction value (1472 x G value
of point 7/3872) (fractions rounded off) and adjust the RB so that it becomes the stan-
dard value.
6) Set the point 3 to the specified gradation, set the G correction value (1152 x G value
of point 7/3872) (fractions rounded off) and adjust the RB so that it becomes the stan-
dard value.
7) Set the point 2 to the specified gradation, set the G correction value (704 x G value of
point 7/3872) (fractions rounded off) and adjust the RB so that it becomes the stan-
dard value.
8) Set the point 1 to the specified gradation, set the G correction value (384 x G value of
point 7/3872) (fractions rounded off) and adjust the RB so that it becomes the stan-
dard value.
9) Write the adjustment value by the MSET0030 command and turn off the AC power.
* RGB initial value of point 7: Set gradation 3872
* RGB initial value of points 1 to 6: G correction value of each point
[Adjustment value]
* According to the “Standard settings” submitted by the Technical Department
[LC70UD1U] teaching set
[Adjustment standard value]
Measuring instrument: [SR-UL2] Technical measuring instrument
MG4R**** Level Reference value Adjustment spec Inspection spec
Point 7 3872
x=0.274
±0.0010 ±0.0020
Point 3 y=0.274
LEV30036
Point 6 3136
X=0.274
±0.0010 ±0.0020
MG3G**** y=0.274
MG3B****
Point 5 2336
X=0.274
±0.0015 ±0.0030
MG3R**** y=0.274
Point 4 1472
X=0.274
±0.0020 ±0.0040
Point 2 y=0.274
LEV20022
Point 3 1152
X=0.274
±0.0030 ±0.0060
MG2G**** y=0.274
MG2B****
Point 2 704
X=0.274
±0.0040 ±0.0080
MG2R**** y=0.274
Point 1 384
X=0.274
±0.0060 ±0.0120
Point 1 y=0.274
LEV10012
MG1G****
MG1B****
MG1R****
Writing
Remarks Setting conditions for inspection
AV MODE: [DYNAMIC]
Monochro: ON
Active Backlight: OFF
Aging Time: Min. 60 minutes
MSET0003 Brightness specification after adjustment.
LC-70UD1U:Min 240cd/m2

Other manuals for Sharp LC-70UD1U