MX-M700N SIMULATION 7 – 14
7-6
Purpose
Setting
Function (Purpose)
Used to set the intermittent aging cycle.
Section
Operation/Procedure
1) Enter the intermittent aging cycle (unit: sec) with 10-key.
2) Press [START] key.
The time entered in procedure 1) is set.
* Set range of interval time: 1 - 999 (sec)
7-8
Purpose
Setting
Function (Purpose)
Used to set the warm-up time display YES/
NO.
Section
Operation/Procedure
1) Select the number corresponding to the warm-up time display
YES/NO.
2) Press [START] key, and the number selected in procedure 1)
is set.
* The setting of this simulation is kept valid until the power is
turned off.
* The warm-up time is displayed by sec.
8
8-1
Purpose
Adjustment/Operation test/Check
Function (Purpose)
Used to check and adjust the operations of
the developing voltage of each color and
the control circuit.
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
Operation/Procedure
1) Select the number that corresponds to the adjustment item
with 10-key.
2) Press the [START] key.
3) Enter the adjustment value with 10-key.
4) Press the [START] key.
(The set value is stored, and the output corresponding to the
set value is outputted for 30sec.)
The operation can be stopped with the [SYSTEM SETTINGS] key.
(The developing bias output voltage adjustment and output check
can be made in each print mode.)
8-2
Purpose
Adjustment/Operation test/Check
Function (Purpose)
Used to check and adjust the operation of
the main charger grid voltage in each
printer mode and the control circuit.
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
Operation/Procedure
1) Select the number that corresponds to the adjustment item
with 10-key.
2) Press the [START] key.
3) Enter the adjustment value with 10-key.
4) Press the [START] key.
(The set value is stored, and the output corresponding to the
set value is outputted for 30sec.)
The operation can be stopped with the [SYSTEM SETTINGS] key.
(The main charger grid output voltage adjustment and output check
can be made in each print mode.)
8-6
Purpose
Adjustment/Operation test/Check
Function (Purpose)
Used to check and adjust the operation of
the transfer voltage and the control circuit.
(Transfer mode)
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)/Transfer
Operation/Procedure
1) Select the number that corresponds to the adjustment item
with 10-key.
2) Press the [START] key.
3) Enter the adjustment value with 10-key.
4) Press the [START] key.
(The set value is stored, and the voltage corresponding to the
set value is outputted for 30sec.)
SIMULATION 7-6
INTERVAL AGING CYCLE SETUP. INPUT TIME AND PRESS START.
(1-999, UNIT: sec)
10
SIMULATION 7-8
WARM UP TIME DISPLAY.
ARE YOU SURE?
1. YES
2. NO
1
Item
Setting
range
Default
1 AUTO Auto mode 0 - 750 495
2 CHARACTER Text mode
3 MIX Text/Photo mode
4 PHOTO Photo mode
5 PRINTER Printer mode
6FAX FAX mode
7 PLUS Reverse developing
bias voltage
0 - 250 150
Item
Setting
range
Default
1 AUTO Auto mode 200 - 1000 580
2 CHARACTER Text mode
3 MIX Text/Photo mode
4 PHOTO Photo mode
5 PRINTER Printer mode
6 FAX FAX mode
SIMULATION 8-1
1
DV BIAS SETTING. SELECT 1-7, AND PRESS START.
1.AUTO 495 2.CHARACTER 495
3.MIX 495 4.PHOTO 495
5.PRINTER 495 6.FAX 495 7.PLUS 150
SIMULATION 8-2
1
MAIN GRID SETTING. SELECT 1-6, AND PRESS START.
1.AUTO 580 2.CHARACTER 580
3.MIX 580 4.PHOTO 580
5.PRINTER 580 6.FAX 580