PN-465U CONNECTION, ADJUSTMENT, OPERATION, AND FUNCTION
2 – 17
■ Others
Function Command
Direc-
tion
Parameter Reply Control/Response contents *
SCREEN SIZE (PC) WIDE WR 1-5 1-5 1: WIDE, 2: NORMAL, 3: DotbyDot, 4: ZOOM1,
5: ZOOM2
o
SCREEN SIZE (AV) WIDE WR 1-5 1-5 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL,
5: DotbyDot
o
VOLUME VOLM WR 0-31 0-31 o
MUTE MUTE WR 0-1 0-1 0: OFF, 1: ON
-
INFORMATION MODEL INF1 R Value o
SERIAL NO SRNO R Value o
BRIGHT VLMP WR 0-31 0-31 Brightness o
TEMPERATURE SENSOR DSTA R 0 Internal temperature normal o
1 Internal temperature abnormal (Standby mode) o
2 Internal temperature abnormal (Temperature is nor-
mal now, but it was abnormal during operation.)
o
3 Internal temperature abnormal
(Brightness of the backlight decreases.)
o
4 Temperature sensor abnormal o
TEMPERATURE ACQUISITION ERRT R Value Temperature at temperature sensors 1 through 3 are
returned in the following forms:
[Sensor 1], [Sensor 2], [Sensor 3]
o
CAUSE OF LAST STANDBY MODE STCA W 0 Initialization o
R 0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power “OFF” by the main power switch
3 Standby mode by RS-232C
4 Waiting mode by No Signal
(Incl: VESA DPMS/DMPM)
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting