PN-465U CONNECTION, ADJUSTMENT, OPERATION, AND FUNCTION
2 – 33
8. MODEL NAME SETTING PROCEDURES
8-1. OPERATING CONDITIONS OF THE MODEL
NAME SETTING TOOL
The operating conditions of the model name setting tool of the informa-
tion display are as follows:
The required RS-232C cable is as shown below. Connect the PC’s
COM port and the RS-232C input terminal of the display.
RS-232C cable : Straight cable (D-Sub 9 pin female-female)
8-2. INSTALLING THE MODEL NAME SETTING
TOOL
The model name setting tool is provided as a compression file,
“PN465_InfoDispSetMN.zip”. When “PN465_InfoDispSetMN.zip” is
decompressed, two files are generated; “InfoDispSetMN.exe” and “Info-
DispSetMN.ini”.
Copy “InfoDispSetMN.exe” and “InfoDispSetMN.ini” to any desired
folder, and execute “InfoDispSetMN.exe”.
8-3. MODEL NAME SETTING
To set the model name with the model name setting tool, follow the pro-
cedures below.
1) Select the model name in the column of Model Name.
When the model is the “PN-4653 select “PN-465”.
When the model is the “PN-465U” 3 select “PN-465U”.
When the model is the “PN-465E” 3 select “PN-465E”.
2) Select the COM port to be used in communication in the column of
COM port.
3) Press [Model Name Write] button.
4) Check to confirm that “OK” is displayed on the lower display.
5) Press [Read] button, and check to confirm that the set model name
is displayed on the lower display.
Note: To set a model name other than the listed above, select “Other
on the Model Name column, describe your desired model name
on the Set Model Name column, and perform procedures 2 to 5.
(This step is not required in normal cases.)
8-4. MODEL NAME CHECK METHOD
Press [DISPLAY] button on the remote controller to indicate the display
information, and check the model name.
8-5.
MODEL NAME SETTING TOOL VERSION CHECK
Display the property of “InfoDispSetMN.exe” with Explorer and check the
production version item to check the model name setting tool version.
OS : Windows98SE, Windows2000, WindowsXP
Communication port : RS-232C port recognized as a COM port
(Which allows communication in 9600bps.)