PN-465U CONNECTION, ADJUSTMENT, OPERATION, AND FUNCTION
2 – 34
9. TEMPERATURE MONITOR SETTING PROCEDURES
Temperature watch setting tool
In the PN-465U, various temperature watch data are saved in the machine.
This tool can read the various temperature watch data and reset the data.
9-1. TEMPERATURE MONITOR SETTING TOOL
INTRODUCTION PROCEDURES
(1) Operating conditions of the temperature monitor set-
ting tool
The operating conditions of the temperature monitor setting tool for the
information display are as follows:
The RS-232C cable required for communication is as stated below.
Connect the COM port of PC and the RS-232C input pin of the display
with the cable.
RS-232C cable : Straight cable (D-Sub 9 pin female-female)
(2) Temperature monitor setting tool installation
The temperature monitor setting tool is provided as a compression file
name “PN465U_TempWatchData.zip”. When “TempWatchLaunch.exe”
“PN465U_Temp-WatchData.zip” is decompressed, the execution file
named “TempWatchLaunch.exe” “[PN465U]TempWatchData.exe”
“TempWatchL- aunch.ini” is generated.
Copy “TempWatchLaunch.exe”, “[PN465U]TempWatchData.exe”,
“TempWatchLaunch.ini” to any desired folder and execute it.
(3) Temperature monitor setting tool version check
To check the temperature monitor setting tool version, use Explorer to
display the property of “[PN465U]TempWatchData.exe”and check
the product version item.
9-2. OPERATING PROCEDURE
(1) Temperature watch setting data read
To read the temperature watch setting data, execute the following pro-
cedures.
1) Connect the information display and the PC with the RS-232C
cable, and turn on the power of the information display.
2) Execute the temperature monitor setting tool, “TemperatureWatch
Launch.exe”, installed in the “Temperature monitor setting tool intro-
duction”.
3) Check to confirm that “PN-465U” is selected in the Combo box.
[“XX” of “PN465XX” are different depending on the model.]
4) Click [RUN] button and check to confirm that “PN-465 Temperature”
is booted.
5) Select the connected port with “COM Port”.
OS : Windows98SE, Windows2000, WindowsXP
Communication port : RS-232C port recognized as a COM port
(Which allows communication in 9600bps.)