42
E
Others
Function
Command Direction
Parameter Reply Control/Response contents *
SCREEN SIZE WIDE WR 1-5 1-5 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2
VOLUME VOLM WR 0-31 0-31
MUTE AUDIO MUTE WR 0-1 0-1 0: OFF, 1: ON -
INFORMATION MODEL INF1 R Value
SERIAL NO SRNO R Value
TEMPERATURE SENSOR DSTA R 0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby mode
2 Internal temperature abnormal occurred (To delete the information of temperature
abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is dimmed
4 Temperature sensor abnormal
TEMPERATURE ACQUISITION ERRT R Value Returns the temperature at the temperature sensors.
Indicates a temperature sensor abnormality when “126” is returned.
CAUSE OF LAST STANDBY MODE STCA W 0 Initialization
R 0 No detectable error has occurred
1 Standby mode by POWER button or MONITOR OFF button
2 Main power off by the main power switch
3 Standby mode by RS-232C or LAN
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting
20 Standby mode by OFF IF NO OPERATION setting
LAN SETUP DHCP CLIENT DHCP WR 0-1 0-1 0: OFF, 1: ON
* Apply the settings to this monitor by NTUP.
IP ADDRESS IPAD WR
XXXXXXXXXXXX XXXXXXXXXXXX
X: Only number is ok. If the number is less than 3 digits, to 3 digits to ll 0.
Example: 192168150001
* Apply the settings to this monitor by NTUP.
SUBNET MASK SBMK WR
XXXXXXXXXXXX XXXXXXXXXXXX
X: Only number is ok. If the number is less than 3 digits, to 3 digits to ll 0.
Example: 255255255000
* Apply the settings to this monitor by NTUP.
DEFAULT GATEWAY DFGW WR
XXXXXXXXXXXX XXXXXXXXXXXX
X: Only number is ok. If the number is less than 3 digits, to 3 digits to ll 0.
Example: 000000000000
* Apply the settings to this monitor by NTUP.
FTP connection FCHE WR 0-1 0-1 0: OFF, 1:ON
Monitor name MNTR WR
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
16 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The eld can be left blank, but spaces cannot be entered.)
FTP Username FUSR WR
XXXXXXXX XXXXXXXX
8 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The eld cannot be left blank, and spaces cannot be entered.)
FTP Password FPAS WR
XXXXXXXX XXXXXXXX
8 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The eld cannot be left blank, and spaces cannot be entered.)
User name USER WR XXXXXXXX XXXXXXXX 8 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The eld can be left blank, but spaces cannot be entered.)
Password PASS WR XXXXXXXX XXXXXXXX 8 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The eld can be left blank, but spaces cannot be entered.)
Auto logout time LOTM WR
00000-65535 00000-65535
Set the time that display terminate a network connection automatically by minutes.
Data port TCPP WR
01025-65535 01025-65535
Set the TCP port number for data communication.
* Apply the settings to this monitor by NTUP.
Reecting LAN setting NTUP W
1
1 Applies the DHCP CLIENT, IP ADDRESS, SUBNET MASK, DEFAULT GATEWAY,
and Data port settings to this monitor.
Controlling the Monitor with a computer (RS-232C)