37
E
n
IP CONTROL SETUP
1. Set IP control setup to ENABLE.
SelectIPCONTROLSETUPwith
or
and press
ENTER
.SelectCHANGEandpress
ENTER
. Select ENABLE with
or
and press
ENTER
.
2. Congureadvancedsecuritysettings.
SelectDETAILSETTINGwith
or
and press
ENTER
.
SelectCHANGEwith
or
and press
ENTER
.
3. Set the login information.
EntertheLOGINIDandPASSWORDwiththesoftware
keyboard(seepage29).
4. Select NEXT and press
ENTER
.
5. Set the control port.
EntertheCONTROLPORTwiththesoftwarekeyboard(see
page29).
6. Select NEXT and press
ENTER
.
7.
Check your settings, select COMPLETE with
or
,
and press
ENTER
.
Command-based control
You can control the monitor using control commands
(see page 33) via terminal software and other appropriate
applications.
Readthemanualfortheterminalsoftwarefordetailed
instructions.
(1) Connect the PC to the monitor.
Use a commercially available LAN cable to connect a PC
to the monitor. (See page 36.)
(2) Send commands to control the monitor.
• ThecommandsusedarethesameasthoseforRS-
232C.Refertothecommunicationprocedure(see
page 31) for operation.
• Usablecommandsareprovidedinthecontrol
command table (see page 33).