42
E
RS-232C command table
How to read the command table
Command: Command eld (See page 38.)
Direction: W When the “Parameter” is set in the parameter eld (see page 38), the command functions as described
under “Control/Response Contents”.
R The returned value indicated under “Reply” can be obtained by setting “????”, “
?” or “???+”
(repeater control) in the parameter eld (see page 38).
Parameter: Parameter eld (See page 38.)
Reply: Response (Returned value)
* : “●” indicates a command which can be used in standby mode/input signal waiting mode regardless of the
STANDBY MODE setting.
“○” indicates a command which cannot be used in standby mode/input signal waiting mode when STANDBY
MODE is set to LOW POWER.
“–” indicates a command which cannot be used in standby mode/input signal waiting mode regardless of the
STANDBY MODE setting.
TIPS
• RSET and MUTE can be used in input signal waiting mode when STANDBY MODE is set to STANDARD.
Power control/Input mode selection
Function
Command Direction
Parameter Reply Control/Response contents *
POWER CONTROL POWR W 0
Switches to standby mode.
●
1 Returns from standby mode.
R 0 Standby mode
1 Normal mode
2 Input signal waiting mode
INPUT MODE SELECTION INPS W 0 Toggle change for input mode. Terminals not selected in INPUT SELECT cannot
be selected.
●
1 DVI-I
2 D-SUB[RGB]
“ERR” when other than RGB is selected for D-SUB of INPUT SELECT.
3 D-SUB[COMPONENT]
“ERR” when other than COMPONENT is selected for D-SUB of INPUT SELECT.
4 D-SUB[VIDEO]
“ERR” when other than VIDEO is selected for D-SUB of INPUT SELECT.
9 HDMI[AV]
“ERR” when PC is selected for HDMI of INPUT SELECT.
10 HDMI[PC]
“ERR” when AV is selected for HDMI of INPUT SELECT.
14 DisplayPort
R 1 DVI-I
●
2 D-SUB[RGB]
3 D-SUB[COMPONENT]
4 D-SUB[VIDEO]
9 HDMI[AV]
10 HDMI[PC]
14 DisplayPort
SCREEN menu
Function
Command Direction
Parameter Reply Control/Response contents *
AUTO ASNC W 1 When the input mode is D-SUB[RGB], DVI-I (analog).
-
CLOCK CLCK WR 0-1200 0-1200 When the input mode is D-SUB[RGB], DVI-I (analog).
Varies depending on the signal.
PHASE PHSE WR 0-63 0-63 When the input mode is D-SUB[RGB], DVI-I (analog).
POSITIONING POSITION OF
THE LONGEST
DIRECTION
HPOS WR 0-100 0-100 0-800 on D-SUB[RGB], DVI-I (analog).
Varies depending on the signal.
POSITION OF
THE SHORTEST
DIRECTION
VPOS WR 0-100 0-100 0-200 on D-SUB[RGB], DVI-I (analog).
Varies depending on the signal.
SIZE SIZE OF THE
LONGEST
DIRECTION
HSIZ WR 0-100 0-100
SIZE OF THE
SHORTEST
DIRECTION
VSIZ WR 0-100 0-100
SCREEN SIZE (PC) WIDE WR 1-5 1-5 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2
○
SCREEN SIZE (AV) WIDE WR 1-5 1-5 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot
RESOLUTION
LONGEST
DIRECTION
RESOLUTION
HRES WR 300-1920 300-1920 When the input mode is D-SUB[RGB], DVI-I (analog).
Only even numbers are valid for parameters.
Varies depending on the signal.
-
SHORTEST
DIRECTION
RESOLUTION
VRES WR 200-1200 200-1200