R-9X55
RIGHTAND LEFT LATCH SWITCHES, STOP SWITCH AND MONITOR SWITCH ADJUSTMENT
If the right latch switch, left latch switch, stop switch and 2. The contact of right latch, left latch and stop
monitor switch do not operate properly due to a mis-adjust-
switches open within 1.2mm gap between upper
ment, the following adjustment should be made.
side of cavity face plate and door when door is open.
1. CARRY OUT 3D CHECKS
3. Re-install the outer case and check for microwave
2. Remove the outer frame assembly referring to “Outer
leakage around the door with an approved micro-
Frame Assembly Removal”.
wave survey meter. (Refer to Microwave Measure-
3. Loosen the one (1) screw holding the latch hook to the
ment.)
oven cavity face plate for each of right and left side.
4. Adjustment the both latch hooks by moving it back and
1%3N!TGR
forward or up and down. No door play allow with tight fit
on the door closed position.
5. Secure the screws with washers firmly.
6. Make sure of the right latch, left latch, stop and monitor
switches operation. If the switches do not activated with
the door closed completely, repeat above procedure.
After the adjustment, make sure of the following:
1. The monitor switch contacts close when the door is
opened.
RIGHT LATCH
Figure C-4. Latch Switch Adjustment.
OUTER FRAME ASSEMBLY REMOVAL
the outer frame assembly can be removed.
1. Remove the five (5) screws.
2. Open the door , push the two hooks of lower frame by
using flat type screw driver and pull the sash to front side.
3. Remove other hooks of top, right and left side and then
Flat type screw drive
DOOR REPLACEMENT AND ADJUSTMENT
DOOR REPLACEMENT
1. CARRY OUT 3D CHECKS.
2. Remove turntable tray and turntable support from oven
cavity.
3. Remove the outer frame assembly. referring to “Outer
Frame Assembly Removal”.
4. Remove the door cam spring and door cam from the
base plate.
5. Loosen three (3) screws on the right oven hinge. remove
the three (3) screws holding the left hinge and remove
the door assembly.
6. Door assembly is now free.
NOTE:When individual parts are replaced. refer to “Door
Disassembly”.
7. On re-installing door, insert the right oven hinge into the
door hinge pin.
8. Then while holding door in place. Make sure door is par-
allel with oven face lines (left and upper side lines) and
the door latch heads pass through the latch holes cor-
rectly.
9. Insert the left oven hinge to the base plate and the
door hinge pin.
lO.Then secure the right and left hinges firmly with the
six $3) mounting screws. Then secure the outer
frame sash.
NOTE:After any service to the door:
Make sure that the right latch, left latch, stop and
monitor switches are operating properly. (Refer
to chapter “Test Procedures”.)
1 I .CARRY OUT 4R CHECKS.
NOTE: After any s&vice to the door;
An approved microwave survey meter should be
used to assure compliance with proper micro-
wave radiation emission limitation standards.
(Refer to Microwave Measurement.)