(3) User program code table
[ES conforming area]
Program
P
code
Selection code:
Set content
Factory setting
Auto clear passing
time setting
1
0: NO
1: 30 sec.
2: 60 sec.
3: 90 sec.
4: 120 sec.
2: 60 sec.
Preheat mode
setting and passing
time setting
2
0: NO
1: 30 sec.
2: 60 sec.
3: 90 sec.
4: 120 sec.
3: 90 sec.
Auto off mode
passing time setting
3
@
1: 30 min.
2: 60 min.
3: 90 min.
4: 120 min.
5: 240 min.
1: 30 min.
Stream feeding
mode setting and
cancel (Only
models with SPF)
4
0: NO
1: YES
0: NO
Auto off mode
setting, cancel
5
0: NO
1: YES
1: YES
@
When auto off mode passing time setting (operation with P code
[3]) is made under the state where the auto off mode is canceled
("[0]: NO" is selected with P code [5]), the machine enters the auto
off mode set conditions without operation with program [5].
[ES conforming area]
Program
P
code
Selection code:
Set content
Factory setting
Auto clear passing
time setting
1
0: NO
1: 30 sec.
2: 60 sec.
3: 90 sec.
4: 120 sec.
2: 60 sec.
Preheat mode
setting and passing
time setting
2
0: NO
1: 30 sec.
2: 60 sec.
3: 90 sec.
4: 120 sec.
0: NO
Auto off mode
passing time setting
3
1: 30 min.
2: 60 min.
3: 90 min.
4: 120 min.
5: 240 min.
0: NO
Since P code
[5] is set to "[0]:
NO," this
setting is set to
[0] though there
is no selection
code specified.
Stream feeding
mode setting and
cancel (Only
models with SPF)
4
0: NO
1: YES
0: NO
Auto power shut off
mode setting, cancel
5
0: NO
1: YES
0: NO
@
When auto power shut off mode passing time setting (operation
with P code [3]) is made under the state where the auto power
shut off mode is canceled ("[0]: NO" is selected with P code [5]),
the machine enters the auto power shut off mode set conditions
without operation with program [5].
8 – 15