28
SMD2470ASY SMD3070ASY
      stated 
2.  Open the drawer and keep it open.
3. To discharge the high voltage capacitor, wait for 60 
seconds. 
4.  Disconnect the wire leads of each switch. 
5.  Remove the screw holding the latch hook to the oven 
flange.
6.  Remove the latch hook from the oven flange.
7.  Remove each switch from the latch hook by pushing the 
one (1) stopper tab holding each switch.
8.  Now, each switch is free.
STOP SWITCH, SECONDARY INTERLOCK SWITCH AND MONITOR SWITCH REMOVAL
1.  Follow the Microwave Drawer disassembly as previously  
Re-install
1.  Re-install each switch in its place. The secondary interlock 
switch is in the lower position and the monitor switch is 
in the top position, located on the left side of the unit. 
The door sensing switch by itself on the right side of the 
unit.
2.  Re-connect wire leads to each switch. Refer to pictorial 
diagram.
3.  Secure the latch hooks with mounting screws to oven 
flange.
4.  Make sure that the monitor switch is operating properly 
and check continuity of the monitor circuit.    Refer to 
chapter "Test Procedure" and "Adjustment procedure".
1.  Follow the Microwave Drawer disassembly as previously 
stated 
2. 
Open the drawer and keep it open.
3. To discharge the high voltage capacitor, wait for 60 
seconds. 
4.  If the door sensing switch, secondary interlock switch 
and monitor switch do not operate properly due to a 
misadjustment, the following adjustment should be 
made.
6.  Loosen the screw holding latch hook to the oven cavity 
flange.
7.  With drawer closed, adjust latch hook by moving it back 
and forth, and up and down. In and out play of the door 
allowed by the upper and lower position of the latch hook 
should be less than 0.5mm. The vertical position of the 
latch hook should be adjusted so that the secondary 
interlock switch is activated with the drawer closed. The 
horizontal position of the latch hook should be adjusted 
so that the monitor switch and drawer sensing switch 
are activated with the drawer closed.
8.  Secure the screws with washers firmly.
9.  Check all of the switches operation. 
STOP SWITCH, SECONDARY INTERLOCK SWITCH AND MONITOR SWITCH
 ADJUSTMENT
After adjustment, check the following. 
1.  In and out play of door remains less than 0.5mm when 
in the latched position. First check upper position of latch 
hook, pushing and pulling upper portion of drawer toward 
the oven face. Then check lower portion of the latch hook, 
pushing and pulling lower portion of the door toward the 
oven face. Both results (play in the door) should be less 
than 0.5mm.
2. The secondary interlock switch interrupts the circuit 
before the door can be opened.
3.  Monitor switch contacts close when door is opened.
4. Door sensing switch contacts open when door is 
opened.
5.  Reassemble the unit and check for microwave leakage 
around door with an approved microwave survey meter. 
(Refer to Microwave Measurement Procedure.
 
Latch Hook Left