REPLACEMENT
PLASMACLUSTER ION
GENERATING UNIT
UNIT REPLACEMENT LAMP
When the total operation time exceeds 17,500
hours, the Unit Replacement Lamp will flash to
indicate that the Plasmacluster Ion Generating Unit
needs replacement.
Operating time
17,500 hours
Flash slowly
Replace the Plasmacluster Ion
Generating Unit
19,000 hours
Flash quickly
No Plasmacluster ions will be
released by the Plasmacluster
Ion Generating Unit.
* The replacement time is not related to the selected
operation mode.
Replacement Plasmacluster Ion
Generating Unit Model
Consult your dealer when purchasing a
replacement Plasmacluster Ion Generating Unit.
UZ-C90M
Disposing of Plasmacluster Ion
Generating Unit
Dispose of used Plasmacluster Ion Generating Unit
according to local laws and regulations.
material:
• Polybutylene Terephthalate
• electronic parts
FILTERS
LIFE OF FILTERS
Filter life varies depending on the room
environment, usage conditions, and location of the
product.
Lifespan of HEPA filter and Deodorizing filter and
replacement suggestions are based on purifying
a room in which 5 cigarettes are smoked per day
and the product's dust collection and deodorizing
performance has declined to half the level of a new
filter.
We recommend replacing the filter more frequently
if the product is used in conditions significantly
more severe (PM2.5 etc.,) than a normal
household.
• HEPA Filter : About 10 years after opening
• Deodorizing Filter : About 10 years after opening
• Humidifying Filter : About 10 years after opening
Replacement Filter Model
Consult your dealer when purchasing a
replacement filter.
Disposing of filters
Dispose of used filters according to local laws and
regulations.
HEPA Filter material:
• Polypropylene • Polyethylene
Deodorizing Filter material:
• Paper • ABS resin
Humidifying Filter material:
• Polyester • Rayon
HEPA Filter
Deodorizing
Filter
Filter Frame
Humidifying
Filter
* Do not dispose
the Filter Frame.
Replacement
Filter
UA-KIL80E UA-KIL60E
HEPA Filter
(1 unit)
UZ-KIL8HF UZ-HD6HF
Deodorizing
Filter (1 unit)
UZ-HG6DF
Humidifying
Filter (1 unit)
UZ-KIL8MF
EN-20
Always be sure to remove the
power plug from the wall outlet.
Remove the claw of Unit Holder (
1
), and remove the
Plasmacluster Ion Generating Unit (
2
).
Attach the New Unit.