[01 DEVICE CONFIG] - [03 REPORT PRINTER] DISPLAY: Setting screen
[REPORT PRINTER]
DISPLAY CONTENTS SELECT ITEM MRS NOTE
TERMINAL# Terminal No. 000-254 000 000 : Self terminal No. This means local device.
1-254 : Except self terminal No. This means
re-routed device.
Re-routing programming is only valid for printer.
CHANNEL# Channel No. 0-7 0 0 : No RS232 channel is assigned.
1-7 : RS232 channel is assigned.
PRINTER Connected printer name BUILT-IN BUILT-IN In case of "BUILT-IN":
The printing method is according to "R/J
PRINTER" programming. (AUTO CUTTER and
LOGO are used the programming data of
"REPORT PRINTER)
TM-T80
TM-T88/85
TM-300
TM-U210
TM-T88 (2)
AUTO CUTTER Aito cutter function NO NO
YES
LOGO TEXT Logo text print PRINT PRINT
NOT PRINT
[01 DEVICE CONFIG] - [04 VALIDATION (VP)] DISPLAY: Setting screen
[VALIDATION (VP)]
DISPLAY CONTENTS SELECT ITEM MRS NOTE
TERMINAL# Terminal No. 000-254 000 000 : Self terminal No. This means local device.
1-254 : Except self terminal No. This means
re-routed device.
Re-routing programming is only valid for printer.
CHANNEL# Channel No. 0-7 0 0 : No RS232 channel is assigned.
1-7 : RS232 channel is assigned.
PRINTER Connected printer name BUILT-IN BUILT-IN
(UP-600)
The UP-700 can not be selected "BUILT-IN".
(Fixed at "TM-295)
TM-295 TM-295
(UP-700)
VP TIMES No. of times of VP 0-9 1 This item is valid only for TM-295