EasyManua.ls Logo

Sharp VL-AD260U - Page 34

Sharp VL-AD260U
97 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
VL-AD260U
4. Color gain adjustment
B spot
R-Y
B-Y
R spot
R level
101°
352°
Burst
B level
Measuring instrument Vector scope
Subject Color bar chart
Tape
Test point VIDEO-OUT (Terminated in 75 )
Adjustment address R GAIN 1C4
B GAIN 1C2
R MAT 1BE
B MAT 1C0
Adjustment level R GAIN; Burst ratio 1.8 ± 0.1
B GAIN; Burst ratio 1.3 ± 0.1
R MAT; 101 ± 2°
B MAT; 352 ± 2°
1) Using the address 1C4, adjust the R level to a burst ratio of 1.8.
With the address 1C2, adjust the B level to a burst ratio of 1.3.
2) Using the address 1BE, adjust the R phase to 101°. With the
address 1C0, adjust the B phase to 352°.
3) Repeat the above steps 1) and 2).
Measuring instrument Vector scope
Subject Gray scale
Tape
Test point VIDEO-OUT (Terminated in 75 )
Adjustment address R-OUT DOOR 6C
B-OUT DOOR 6E
Adjustment level R-OUT DOOR; 0 ± 3 %
B-OUT DOOR; 0 ± 3 %
1) Attach the color temperature conversion filter (JiGHOYA-LB165) to the front of the lens.
2) Using the addresses R-OUT DOOR 6C and B-OUT DOOR 6E, adjust the spot to the center.
3) Take off the color temperature conversion filter.
5. Out door white balance adjustment
Center point
Spot
R-Y
B-Y
When you have finished, write FF to the address 00 to exit camera signal
adjustment mode.

Related product manuals