34
VL-AD260U
4. Color gain adjustment
B spot
R-Y
B-Y
R spot
R level
101°
352°
Burst
B level
Measuring instrument Vector scope
Subject Color bar chart
Tape
Test point VIDEO-OUT (Terminated in 75 )
Adjustment address R GAIN 1C4
B GAIN 1C2
R MAT 1BE
B MAT 1C0
Adjustment level R GAIN; Burst ratio 1.8 ± 0.1
B GAIN; Burst ratio 1.3 ± 0.1
R MAT; 101 ± 2°
B MAT; 352 ± 2°
1) Using the address 1C4, adjust the R level to a burst ratio of 1.8.
With the address 1C2, adjust the B level to a burst ratio of 1.3.
2) Using the address 1BE, adjust the R phase to 101°. With the
address 1C0, adjust the B phase to 352°.
3) Repeat the above steps 1) and 2).
Measuring instrument Vector scope
Subject Gray scale
Tape
Test point VIDEO-OUT (Terminated in 75 )
Adjustment address R-OUT DOOR 6C
B-OUT DOOR 6E
Adjustment level R-OUT DOOR; 0 ± 3 %
B-OUT DOOR; 0 ± 3 %
1) Attach the color temperature conversion filter (JiGHOYA-LB165) to the front of the lens.
2) Using the addresses R-OUT DOOR 6C and B-OUT DOOR 6E, adjust the spot to the center.
3) Take off the color temperature conversion filter.
5. Out door white balance adjustment
Center point
Spot
R-Y
B-Y
When you have finished, write FF to the address 00 to exit camera signal
adjustment mode.