VL-SDPOU
6. INSPECTION AND MAINTENANCE ITEMS AND INTERVALS
In order to keep the mechanical section always in good condition, perform the following inspection and maintenance at regular intervals.
In addition, after repair, perform the following maintenance items regardless of how long the user has been using the unit.
6-1. List of inspection and maintenance items
0 l l l Replace. 0. l l Clean. A* l l Lubricate. ** l l Check.
l Head hole clogging
Replace the drum a&y if the
video head is cleaned but the
envelope is not still appeared.
(When the envelope is normal,
refer to “11. USEFUL TIPS”.)
specially the lower drum helical
l The tape becomes slack.
l Block-type noise
l Abnormal noise
l The tape becomes slack.
perform within the standard.
l The play-back image is
[Oil] Cosmo Hydro HV22, HVl 00 [Screw lock] Three Bond 1401 B
[Grease] Moly Coat YM-103
[Cleaning liquid] industrial-use ethyl alcohol
6-2. Precautions
(1) When replacing any part, always replace the cut washer that was
removed with a new one.
(2) This mechanism does not have control adjustment. If the control cannot
be set as required, clean and or replace parts.
(3) On the oil
a) Always use the specified oil. (Using another kind of oil can cause
various kinds of trouble.)
b) Always use clean oil, without any mixed-in dirt, to lubricate bearings.
(Using oil with dirt mixed in can cause the bearings to wear or to stick.)
c) One drop of oil is the amount shown in the Fig. 1, on the point of a pin.
(4) Perform circuit repair, tape running adjustment, etc. with the cassette
controller assembly attached to the mechanism.
(5) To operate the mechanical section alone, remove the FPC of loading motor
from the connector (section B in the Fig. 2), and apply voltage to the loading
motor to drive it. The voltage between terminals must be DC3V or less.
(Forcing the gears to turn by hand entails danger of breakage.)
(6) To install the cassette controller, push section A in the Fig. 2. Do not push
anything else.
(7) Do not deform any of the mechanical parts.
Fig. 1
6-1