XE-A202V CAUTION TO BE USED WHEN CONNECTING THE RS-232 CABLE
– 16 –
APPENDIX: RS232C CABLE
The RS-232C cable has the following internal connections:
(Equivalent to a cross cable used in the conventional connection of
ECR-ECR)
SD : TRANSMITTED DATA
RD : RECEIVED DATA
DTR : DATA TERMINAL READY
DSR : DATA SET READY
RTS : REQUEST TO SEND
DCD : DATA CARRIER DETECTOR
CTS : CLEAR TO SEND
CHAPTER 7. CAUTION TO BE USED
WHEN CONNECTING
THE RS-232 CABLE
When connecting the RS-232 cable to the XE-A212, be sure to observe
the following condiiton:
SD
3
SD
RD
CTS
RD
2
6
8
3
2
6
8
55
SG
RTS
7
DCD
1
DTR
4
DSR
7
1
4
CTS
SG
RTS
DCD
DTR
DSR
9PIN D-SUB 9PIN D-SUB
Secure the attached core (RCORF6699BHZZ) to the RS-232
cable in the area within 20mm from the connector.
[This is a necessary procedure to support the EMI (Electronics
Magnetic Interface).]
RS232 CONNECTOR
Within
20mm
Secure the core
(RCORF6699BHZZ)
to the cable in the area
within 20 mm from the
connector with a lock
band.