2 – 3
VOLUME test (TEST 3)
Starting from level 23 (default), check all the levels (0 - 23 - MAX).
TIMER test (TEST 4)
At 1:05, the power turns on to activate the tape function, and turns off after 90 seconds (equivalent to 90 minutes on the unit).
Display test (TEST 5)
When test mode is activated, the entire display lights up. As the “PLAY” key is pressed, half of the display lights up alternately.
ALL KEY test (TEST 6)
In the test mode, hold down all the buttons on the main unit and then press the “ON/STAND-BY”button. “OK” appears.
If only the “ON/STAND-BY” button is pressed, “ERROR” appears.
Tuner clear test (TEST 7)
All tuner preset stations are cleared.
Soft reset test (TEST 8)
All data in RAM is cleared.