Status Monitoring (ALARM)
Monitor the output selected by D8059.
High-speed input count start
After setting, start high-speed input pulse counting.
High-speed input count
value clear
After setting, the high-speed input count value is reset
to zero.
0: Inverter PN is not over-voltage 1: Inverter PN is
over-voltage
0: Inverter PN is not under low voltage
1: Inverter PN low voltage
0: PLC is not running
1: PLC is in RUN state
Inverter is about to reset
0: The inverter will not be reset
1: The inverter will reset (Note 2)
Inverter Tuning status
monitoring
0: The inverter is not in Tuning state
1: The inverter is in Tuning state
0: Not sure
1: The inverter is in a power-off state
Note: 1. Special operations can be performed only when M8035 is 0. The special operation refers to the
operation of D8153. M8035 can be cleared through communication, PLC program and PLC STOP.
2. When M8068 is 1, it means the inverter is about to be reset. At this time, the customer can make
preparations for the inverter reset in advance.
3. When M8049 is OFF, D8059 and the existing record data of D8060 will not be cleared.