Flag bit: none
S1
: The lower limit of the area comparison.
S2
: The upper limit of the area comparison.
S
: Comparison
value.
D
: Comparing results.
The value of
S1
must be less than the value of
S2
. The result of the comparison is shown by
D
.
If the target points to M0, it will automatically occupy M0~M2.
The ZCP instruction is executed when X0 is ON. When X0 is OFF, ZCP is not executed, and the state remains as before
X0 is OFF.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SF3 Series and is the answer not in the manual?