1. Connect chilling water inlet/outlet of machine with hoses according to above
picture.
2. Bactericide and water (according to purchased bactericide mixing requirement
for specific proportion) proportional to solution and pour into the water tank of
machine, then start-up pump cleaning of the machine.
3. After discharging the bactericide solution when cleaning finished, it should
repeat more turns of water washing to water tank for ensuring theres no
bactericide solution left in the system.