    jeremyriosSep 12, 2025
    What to do if my Shott Heat Pump does not work and error message EE 2 is displayed?
    • V
      veronica47Sep 12, 2025
      If your Shott Heat Pump displays error message EE 2 and isn't working, the ambient temperature sensor may be incorrectly connected or defective. Check the sensor resistance value and replace it if necessary. You can also replace the control board.
  • M
    Monica OchoaSep 12, 2025
    What to do if my Shott BP-50HS-A is running and error message EE 3 is displayed?
    • B
      Barbara OconnorSep 12, 2025
      If your Shott Heat Pump displays error message EE 3 while running, the compressor temperature sensor may be incorrectly connected or defective. Check the sensor resistance value and replace if necessary. You can also replace the control board.
  • T
    Thomas MullinsSep 10, 2025
    What to do if my Shott BP-50HS-A does not work and error message EE 1 is displayed?
    • D
      davidhallSep 10, 2025
      If your Shott Heat Pump displays error message EE 1 and isn't working, the pool temperature sensor may be incorrectly connected or defective. Check the sensor resistance value and replace it if necessary. You can also replace the control board.
  • C
    Courtney RodriguezSep 9, 2025
    What to do if my Shott BP-50HS-A Heat Pump does not start?
    • T
      Tami BrownSep 9, 2025
      If your Shott Heat Pump doesn't start, first ensure that the 3 minutes required for pump start have elapsed. If the pool temperature is at or above the set temperature, the pump will only start when the pool temperature drops below the set temperature. Finally, confirm that the pump operating mode is set to the required mode.
  • S
    Suzanne BrownSep 8, 2025
    Why is my Shott Heat Pump not working and error message EE 6 is displayed?
    • E
      Elaine NelsonSep 8, 2025
      If your Shott Heat Pump displays error message EE 6 and isn't working, it could be due to several reasons. The compressor temperature might be too high, so wait until it drops. There could be a refrigerant circuit leak, so check for leaks and replace any defective parts. Alternatively, the capillary circuit might be clogged, in which case it should be replaced.
  • I
    Ian HernandezAug 23, 2025
    What to do if my Shott Heat Pump is running but the water is not heating?
    • J
      Justin RobbinsAug 23, 2025
      If your Shott Heat Pump is running but not heating the water, first ensure that air exits the front part of the heat pump. If the heat pump was just installed, allow 24 to 48 hours to reach the set temperature. If the pool water has significantly cooled since the last use, it may take 24 to 36 hours to reach the desired temperature.
  • J
    Justin ClarkSep 6, 2025
    What does it mean if my Shott BP-50HS-A displays error message EE 8 and doesn't work?
    • A
      alexander69Sep 6, 2025
      If your Shott Heat Pump displays error message EE 8 and does not work, it indicates that the control board wiring is defective. Check the wiring.
  • S
    Stephanie MitchellSep 5, 2025
    What does it mean if my Shott BP-50HS-A Heat Pump displays error message EE 4?
    • B
      Brenda LarsenSep 5, 2025
      If your Shott Heat Pump is running and displays error message EE 4, it means the automatic defrost did not run correctly. Increase the water flow at the pump inlet.
  • L
    Lisa HillSep 4, 2025
    What does it mean if my Shott Heat Pump displays error message EE d?
    • C
      Cynthia BrownSep 4, 2025
      If your Shott Heat Pump displays error message EE d, it means there are functional parameter changes and parameter 9 is not set to 1. Set the correct parameter values to 1.
  • C
    Carolyn Scott DDSSep 3, 2025
    What does it mean if my Shott BP-50HS-A Heat Pump displays error message EE 3?
    • S
      Scott GriffinSep 3, 2025
      If your Shott Heat Pump is running and displays error message EE 3, it indicates that the compressor temperature sensor is incorrectly connected or defective. Check the sensor resistance value and replace it if necessary.

Summary

General Warnings and Information

CE Declaration

Formal statement of compliance with EU directives for the machinery.

Warranty

General Conditions

Details the warranty period, conditions, and exclusions for the product.

Special Conditions

Specific warranty applicability and validation requirements within EU member countries.

Restrictions

Limitations on warranty coverage, such as consumer sales and misuse.

Symbol Key

Safety Regulations and Energy Savings

Safety Regulations for Heated Pools

Essential safety guidelines for using heated swimming pools to prevent accidents.

Energy Savings

Tips and recommendations for optimizing heat pump energy consumption and performance.

General Information and Definitions

Product Presentation

Product Scope

Defines the intended use and application of the SERIES BP heat pumps.

Heat Pump Composition

Technical Specifications

Installation

Inspection and Handling

Procedures for checking the unit upon arrival and safe methods for handling.

Positioning Requirements

Guidance on selecting an appropriate location and mounting the heat pump.

Clearance, Noise, and Disposal

Hydraulic Connections

Electrical Connections

Mains Connection

Socket Installation

Steps for installing the mains connection socket, ensuring correct IP grade and grounding.

Cord Replacement

Procedure for safely replacing the heat pump's mains connection cord.

Commissioning and Preliminary Checks

Operations and Use

Control Panel Overview

Explanation of the heat pump control panel buttons, display, and basic operations like turning on/off.

Heat Pump Operations

Starting, Mode, and Temperature Settings

Procedures for starting the unit, selecting operating modes, and adjusting set temperatures.

Working Temperature and Automatic Settings

Configuration of minimum working temps, automatic start, and standby modes.

Defrost, Key Lock, and Sensor Display

Functions for manual defrost, locking controls, and viewing sensor temperatures on the display.

Functional Parameter Settings

Defrost and Protection Parameters

Configuration options for defrost cycles and compressor protection settings.

Temperature Range Parameters

Adjusting pool temperature regulation, defrost start/stop temperatures.

Defrost Timing and Compressor Parameters

Setting defrost repetition time, duration, and compressor temperature limits.

Restart, Mode, and Deviation Parameters

Configuring automatic restart, operating mode, and temperature deviation settings.

Control Mode & Manometer Use

Selecting control mode and understanding manometer readings for pressure monitoring.

Control and Safety Devices

Temperature and Flow Sensors

Details on ambient, pool, flow, compressor, and plate heat exchanger sensors.

High Pressure Sensor Function

Explains the role of the high pressure sensor in protecting the compressor.

Low Pressure Sensor Function

Explains the role of the low pressure sensor in protecting the compressor.

Sensor Resistance Values

Temperature Sensor Resistance Values

Table providing resistance values for temperature sensors at various temperatures.

Compressor Temperature Sensor Resistance Values

Table providing resistance values for the compressor temperature sensor.

Maintenance and Troubleshooting

Routine Maintenance Checks

Tasks for users and specialized technicians for regular checks and upkeep.

Winter Protection and Spring Commissioning

Procedures for protecting the unit during winter and recommissioning in spring.

Troubleshooting Common Problems

Identifies common issues like no start, no heating, or frost, and provides solutions.

Troubleshooting Error Messages

Guides for resolving specific error codes displayed by the heat pump.

Spare Parts

Spare Parts for BP-xxHS-A Models

Lists and illustrates spare parts for the BP-xxHS-A model, with part numbers.

Spare Parts for BP-xxWS-B Models

Lists and illustrates spare parts for the BP-xxWS-B model, with part numbers.

Special Notes on Part Replacement

Specific instructions for replacing key components like manometer, sensors, filter, and capillary.

Shott BP-50HS-A Specifications