Event Log
The event log provides a detailed account of activity from the moment the device is powered on. The log collects up to 1,000
activity entries and time-stamps them relative to the last power cycle. The entries are stored in the internal memory, and are
not cleared when the device is power-cycled. The Export feature creates a CSV (comma separated values) document to save
and sort the log data.
Refer to the log file for details when troubleshooting or consulting with Shure Systems Support.
To view the event log:
Open the Help menu
Select View Event Log
Severity Level
Information
An action or event has been successfully completed
Warning
An action cannot be complete, but overall functionality is stable
Error
A problem has occurred that could inhibit functionality.
Log Details
Description
Provides details on events and errors, including IP address and subnet mask.
Time Stamp
Power cycles:days:hours:minutes:seconds since most recent boot-up.
Event ID
Indicates event type for internal reference.
Tip: Use the filter to narrow down results. Select a category heading to sort the log.
Levels and Metering
Adjusting Input levels
Check the source level before it reaches the Network Interface:
Verify that the networked microphones or other Dante sources are operating at nominal output levels.
Levels for Microflex Advance
™
microphones are adjustable through their web application.
Adjust the digital gain in the Network Interface web application:
Use the faders or manually enter a gain value.
The digital gain adjusts the level of the signal before it reaches the analog circuitry.
Set these levels as high as possible without reaching the peak level (0 dB) on the meter.