Ethernet cables should be:
Cat5e or better
Shielded
For more information, see our FAQ about switches to avoid.
Dante Flows for Shure Devices
Dante flows get created any time you route audio from one Dante device to another. One Dante flow can contain up to 4 audio
channels. For example: sending all 5 available channels from an MXA310 to another device uses 2 Dante flows, because 1
flow can contain up to 4 channels.
Every Dante device has a specific number of transmit flows and receive flows. The number of flows is determined by Dante
platform capabilities.
UnicastandmulticasttransmissionsettingsalsoaffectthenumberofDanteflowsadevicecansendorreceive.Usingmulti-
cast transmission can help overcome unicast flow limitations.
Shure devices use different Dante platforms:
Dante Platform
Shure Devices Using Plat-
form
Unicast Transmit Flow
Limit
Unicast Receive Flow Limit
Brooklyn II
ULX-D, SCM820, MXWAPT,
MXWANI, P300, MXCWAPT
32 32
Brooklyn II (without SRAM)
MXA920, MXA910, MXA710,
AD4
16 16
Ultimo/UltimoX
MXA310, ANI4IN, ANI4OUT,
ANIUSB-MATRIX, ANI22,
MXN5-C
2 2
DAL IntelliMix Room 16 16
Learn more about Dante flows in our FAQs or from Audinate.
IP Ports and Protocols
Shure Control
Port TCP/UDP Protocol Description
Factory De-
fault
21 TCP FTP Required for firmware updates (otherwise closed) Closed
22 TCP SSH Secure Shell Interface Closed
23 TCP Telnet Not supported Closed
53 UDP DNS Domain Name System Closed