RF Coverage
Optimal Placement of the Access Point
Place the Access Point in the center of the installation for best coverage
Using Multiple 2- or 4-Channel Access Points
The MXW access point uses two sets of antennas to cover the operating spectrum. Each antenna set covers half of the times
lots used for MXW channels. Eight-channel units use both antenna sets simultaneously; two- and four-channel units use one
set at a time, operating on half of the available timeslots. The full spectrum can be covered they are configured to alternating
antenna sets.
When an installation uses multiple two- or four-channel access points (APT2 or APT4), configure the access point settings to
maximize channel count. This is particularly important for APTs that are mounted in the same or neighboring rooms.