EasyManuals Logo

Shure P4800 User Manual

Shure P4800
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Applications Group: (847) 600-8440 Shure Inc.
Fax: (847) 600-8444 5800 Touhy Ave
Niles, IL 60714 USA
_______________________________________________________________________________________
MICROPHONES AND ELECTRONIC COMPONENTS
Page 1
6/15/04 RW
Using the P4800 with AMX / Crestron Systems
Wiring
The P4800 uses a standard 7 wire RS-232 port for control. Crestron and AMX controllers use 5 wire RS-232. In order to
use a P4800 with Crestron or AMX, a custom cable will need to be built. The following diagram shows the cable. For a 5
volt supply, the resistor should be 1kohms.
All wires are straight through. The 9 pin connectors have numbers stamped on them. Follow those stamped numbers for
the pin out. Connect the RX, TX, GND, RTS, and CTS to the five wire RS-232 port on the control unit. The P4800 requires
a voltage of 5 to 12 volts on the DTR line. This voltage tells the microprocessor to accept any data that it receives on the
TX line.
Computer Interface – RS232 Pinout
Specifications
Baud: 19200
Data bits: 8
Stop bits: 1
Parity: none
Flow control: none