Details the physical components and parts of the MF5700 flow meter and valve assembly.
Explains the symbols and information displayed on the MF5700's LCD screen.
Describes the wire assignment and specifications for the MF5700 power and data cable.
Provides the physical dimensions and specifications of the MF5700 meter.
Guides users on verifying product specifications before operation for optimal performance.
Explains the procedure for checking for gas leakage before performing any measurement.
Covers powering the meter using batteries or external DC and establishing digital data connections.
Describes optional wireless data transmission methods and the associated mobile application.
Introduces the meter's menu structure and navigation using the 3-key interface.
Details how to start the measurement process after powering up the meter.
Explains how to access the meter's menu settings via password verification.
Guides on setting the Modbus address for RS485 communication.
Details how to configure the baud rate for RS485 communication.
Explains how to reset or calibrate the meter's zero flow offset for accuracy.
Describes how to set the Gas Conversion Factor for various gas types.
Allows users to select between cycle or fixed display modes for the meter's screen.
Covers selecting the display language, currently English or Chinese.
Explains how to manually open or close the integrated valve on the meter.
Guides on setting an upper limit alarm for instant flow rate.
Details setting a lower limit alarm for instant flow rate.
Explains how to set an alarm for accumulated or totalized flow rate limits.
Provides instructions on changing the default password for enhanced data safety.
Details how to reset the accumulated or totalized flow rate counter.
Explains how to exit the current MENU settings and return to the main display.
Describes the sleeping mode feature for power saving when the meter is battery-powered.
Explains how the meter wakes up from sleeping mode automatically or manually.
Provides a flowchart illustrating the key sequences for accessing and configuring meter settings.
Details the hardware connection requirements for RS485 Modbus communication.
Lists the required UART communication parameters for PC and Modbus RTU.
Explains the frame structure used in the standard Modbus RTU protocol.
Details the Modbus function codes used for reading and writing registers.
Provides information on available registers for data access and parameter setting.
Explains the product part number composition and selection criteria.
Provides information on how to order products and contact customer support.
Lists detailed technical specifications for the MF5706, MF5708, and MF5712 models.
Explains the MEMS thermal calorimetric sensing technology used in the MF5700 series.
Provides advice and precautions to ensure optimal performance and accuracy of the meter.
Offers guidance on comparing MF5700 data with third-party reference meters.
Highlights the importance of fluid cleanliness for measurement accuracy and meter function.
Discusses considerations and potential errors when using the meter with gases other than air.
Lists common phenomena, their possible causes, and recommended actions for troubleshooting.
Details the product warranty terms, conditions, exclusions, and liability limitations.
Provides contact information for customer service, orders, and general inquiries.
Describes the components and purpose of the product evaluation kit for performance assessment.
Lists the revision history of the user manual, including dates and changes.