GC315xx and GC400xx Technical Manual 89
The display is turned off and the electronic of the controller, the modem and the GPS receiver
work with reduced modalities.
The internal accelerometer is able to detect whether the device, and therefore the control panel
or the genset, is moved and creates an appropriate event which is sent to Si.Mo.Ne. system
together with the position data.
Through parameters P.0594 and P.0595 it is possible to set the level of sensibility of the
accelerometer and the number of accelerations to be detected in a time of two minutes before
creating the accelerometer event. This to avoid the creation of events due to vibrations, impacts
or wind blows and not therefore to effective movement. Every two minutes the acceleration count
automatically restart from zero.
There being no further accelerometer events and persisting low or absent voltage supply
conditions, the device is brought back to energy saving mode.