Chapter 1 Operating Instructions
AR60
16 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8007406/YW24/2016-05-13
Subject to change without notice
General
en
1 General
The AR60 laser alignment aid is a device for aligning various SICK
optical sensors, such as for example photoelectric switches and light
curtains.
1.1 The AR60 at a Glance
Compact housing.
Battery power supply – no need for mains power
1)
.
Surface to which various adapters can be screwed.
Easy-to-handle laser pointer.
No. 50, dated June 24, 2007
deviations pursuant to Laser Notice
21 CFR 1040.10 and 1040.11 except for
P 1 mW (cw), λ = 630-680 nm
LASER RADIATION
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
Complies with IEC/EN 60825-1:2007,
Using the AR60 laser alignment aid, optical sensors (sender/receiver)
may be quickly and easily aligned during installation, even before
power is supplied to the sensors.
The AR60 laser alignment aid is of great advantage when the beam
array is deflected by means of deflector mirrors. The alignment
(adjustment) of sender/receiver and deflector mirrors can thus be
carried out very rapidly by one person.
1)
Batteries are to be disposed of separately in accordance with statutory regulations.
Fig.
1
:
Construction of the
AR60 laser alignment aid
Connection screw
Micro
-
battery
2 x 1.5 V
On/Off switch
Light emission
approx. 6 mm
Remove cover to
change batter
y
Spirit level