9 Technical data
9.1 Technical data
Table 4: Features
Features
Variant with cable
ent
ry
Variant with plug con‐
nector
Housing material Fiberglass-reinforced thermoplastic
Enclosure rating (IEC 60529) IP 67
Mechanical service life 1 × 10
6
B
10d
(EN IS
O 13849) at DC-13 100 mA / 24 V 5 × 10
6
Switching operation with small load
Type Type 2 (EN ISO 14119)
Coding level of the actuator Low coding level (EN ISO 14119)
Ambient operating temperature –20 °C … +55 °C
Connection type 3 × M20
Plug connector, 1 x
M12 (8-pin)
Max. actuation speed 20 m × min
–1
Max. actuation frequency 1,200 × h
–1
Pollution degree
(e
xternal, according to EN 60947)
3 × (industry)
Max. actuating force at 20 °C 35 N
Max. force against which unlocking is possible 20 N
Max. retaining force, unlocked 30 N
1)
Locking force F
ma
x
Actuator, straight and radial 2,500 N
Actuator, angled 1,500 N
Locking force F
Zh
ac
cording to (EN ISO 14119)
(F
Zh
= F
max
/1.3)
2,000 N
Minimum door radii see table 8
1)
45 N at i110-E0313S06
Table 5: Electrical data
Electrical data
Variant with cable
ent
ry
Variant with plug con‐
nector
Thermal current l
t
h
4 A 1 A
Switching principle Slow action switching element
Wire cross-section, (rigid/flexible) 0.34 mm² … 1.5 mm²
Rated insulation voltage U
i
250 V 30 V
Rated impulse withstand voltage U
im
p
2.5 kV 1.5 kV
Utilization category (IEC 60947-5-1) AC-15: 230 V/4 A;
DC
-13: 24 V/4 A
AC-15: 24 V/1 A;
DC-13: 24 V/1 A
Min. switching voltage
1)
12 V
Min. switching current at 24 V DC 1 mA
Conditional rated short-circuit current 100 A
TECHNICAL DATA 9
8020543/17K9/2020-06-08 | SICK O P E R A T I N G I N S T R U C T I O N S | i110 Lock
23
Subject to change without notice