EasyManua.ls Logo

SICK LMS511-10100 PRO Outdoor - User Manual

SICK LMS511-10100 PRO Outdoor
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
OPERATING INSTRUCTIONS
LMS5xx
LASER MEASUREMENT SENSORS

Table of Contents

Questions and Answers:

SICK LMS511-10100 PRO Outdoor Specifications

General IconGeneral
BrandSICK
ModelLMS511-10100 PRO Outdoor
CategoryAccessories
LanguageEnglish

Summary

About this document

Information regarding the operating instructions

Provides essential information on handling SICK AG laser measurement sensors and safety.

Scope

Covers safe mounting, installation, commissioning, configuration, and maintenance of LMS5xx variants.

Depth of information

Outlines the topics covered in the operating instructions for the LMS5xx.

Explanation of symbols

Explains warning symbols, signal words, and typographic conventions used in the document.

Further information

Directs users to online resources for additional documentation and product details.

Customer service

Advises users to contact customer service for technical information and provides guidance before calling.

For your safety

Correct use

Defines the intended applications and correct usage of the LMS5xx sensor.

Incorrect use

Lists prohibited uses and states the LMS5xx is not a safety component.

IP technology

Explains SICK's approach to IP technology, emphasizing customer responsibility for security measures.

Limitation of liability

Outlines the manufacturer's disclaimer for damages caused by improper use or failure to follow instructions.

Modifications and conversions

Warns about dangers from modifications and states that unauthorized changes void warranty claims.

Requirements for skilled persons and operating personnel

Details the qualifications required for personnel handling the LMS5xx safely.

General safety notes and protective measures

Provides essential safety notes and protective measures for correct and safe use of the LMS5xx.

Hazard warnings and operational safety

Covers laser radiation hazards, warnings, and safety regulations for operation.

Quick stop and restart

Describes the procedure for safely switching the LMS5xx off and back on.

Environmental protection

Highlights the LMS5xx's minimal environmental impact and low power consumption.

Repair

States that repairs must only be performed by authorized SICK AG personnel.

Product description

Delivery

Lists the components included in the LMS5xx delivery and provides links to product information.

Device variants

Details different LMS5xx device variants, their purpose of use, range, heating, and enclosure rating.

Type code

Explains the marking scheme for standard LMS5xx variants and their characteristics.

Special features of the LMS5 xx

Lists the special features of LMS5xx variants, including field of view, scanning frequency, and data interfaces.

Differences between the LMS5 xx Lite, PRO and Heavy Duty versions

Compares the key differences between LMS5xx Lite, PRO, and Heavy Duty versions.

Controls and status indicators

Describes the user interface, LEDs, and 7-segment display for monitoring the LMS5xx status.

Operating principle of the LMS5 xx

Explains how the LMS5xx scans the environment using laser pulses and measures distance and angle.

Applications

Lists various applications for the LMS5xx, such as object measurement and detection.

Measurement of objects

Details basic parameters for measuring objects, including scanning frequency and distance.

Field application

Explains the integrated field application for collision protection, surveillance, and access monitoring.

Inputs and outputs

Describes the digital switching inputs, encoder inputs, and digital switching/relay outputs of the LMS5xx.

Data interfaces

Covers Ethernet, serial host, and USB interfaces for configuration and data transmission.

Data communication using telegrams

Explains how the LMS5xx communicates with a host using telegrams.

Planning

Outlines system requirements, mounting requirements, and considerations for planning the LMS5xx installation.

Transport and storage

Transport

Provides notes for safe transport, emphasizing proper packaging and handling.

Transport inspection

Guides users on checking delivery for completeness and damage upon receipt.

Storage

Specifies conditions for storing the LMS5xx to maintain its integrity.

Mounting

Overview of the mounting steps

Outlines the main steps involved in mounting the LMS5xx.

Preparations for mounting

Lists components, materials, accessories, and tools required for mounting.

Dismanteling the system

Provides instructions for safely dismantling the LMS5xx system.

Electrical installation

Overview of the installation steps

Summarizes the steps for wiring inputs, outputs, data interfaces, and power.

Conditions for safe operation of the LMS5 xx in an installation

Details conditions for safe operation, focusing on ground potential and equipotential bonding.

Connections of the LMS5 xx

Describes the various connections available on different LMS5xx variants (USB, Ethernet, M12, etc.).

Preparing the electrical installation

Covers supply voltage, wire cross-sections, cable lengths, and general conditions for data interfaces.

Perform electrical installation on the LMS5 xx

Details the steps for connecting the LMS5xx via USB and Ethernet interfaces.

Commissioning and configuration

Overview of the commissioning steps

Outlines the steps for commissioning, including software installation and communication setup.

SOPAS ET configuration software

Introduces the SOPAS ET software, its functions, and system requirements.

Establish communication with the LMS5 xx

Guides on establishing communication via Ethernet, USB, or serial interfaces.

Initial commissioning

Explains how to adapt the LMS5xx to the local environment using parameter sets.

Connection and test measurement

Describes how to verify functionality using the graphic scan view in SOPAS ET.

Maintenance

Maintenance during operation

Covers routine maintenance, primarily cleaning the front screen of the LMS5xx.

Exchanging an LMS5 xx

Provides instructions for replacing a defective LMS5xx unit with a new or repaired one.

Decommissioning

Details procedures for decommissioning, including proper disposal of the LMS5xx.

Troubleshooting

In the event of faults or errors

Advises to cease operation if a malfunction cause is unclear and to stop the system if an error cannot be identified.

Error displays of the indicator lights

Explains the meaning of LED indicators and their corresponding causes and rectification steps.

Indications of the 7-segment display

Lists indications on the 7-segment display, their causes, and corrective actions.

Detailed error analysis

Describes how errors are output in stages and mentions field evaluation monitor and logging for analysis.

SICK Support

Guides users on contacting SICK Support if errors cannot be eliminated and provides important pre-call information.

Technical specifications

Data sheet LMS5 xx laser measurement sensor

Presents detailed technical specifications for the LMS5xx sensor.

Operating range diagrams

Shows graphical representations of the LMS5xx operating ranges based on resolution and remission.

Dimensional drawings

Provides detailed dimensional drawings for the LMS500, LMS511/531/581, and mounting kits.

Annex

Ordering information

Directs users to the web product page for ordering information on LMS5xx and accessories.

EU declaration of conformity

Provides information on obtaining the EU declaration of conformity for the LMS5xx.

Glossary

Defines key terms and concepts used within the operating instructions.

Abbreviations

Lists and defines abbreviations used throughout the document.

List of Figures

Provides a comprehensive list of all figures referenced in the manual.

List of Tables

Provides a comprehensive list of all tables referenced in the manual.

Related product manuals