OPERATING INSTRUCTIONS
LMS1xx
LASER MEASUREMENT SENSORS

Table of Contents

Questions and Answers:

SICK LMS100 Specifications

General IconGeneral
Field of View190°
Protection RatingIP67
Scanning Angle270°
Measurement Accuracy± 30 mm
Operating Voltage24 V DC
Protection ClassIII
InterfaceEthernet, RS-422
TypeLaser Scanner
Output SignalEthernet
Operating Temperature-10 °C ... +50 °C
Angular Resolution0.5°
Scanning Frequency25 Hz

Summary

For your safety

Correct use

Defines the intended applications and proper usage of the LMS1xx sensor.

Incorrect use

Details prohibited uses and limitations of the LMS1xx.

Modifications and conversions

Warns about dangers and warranty voidance from modifications to the device.

Requirements for skilled persons and operating personnel

Specifies the necessary training and qualifications for safe operation.

Hazard warnings and operational safety

Covers essential safety notes, warnings, and general operational safety.

Product description

Operating principle of the LMS1xx

Explains how the electro-optical laser measurement sensor functions.

Data interfaces

Describes the available Ethernet, CAN, Serial host, and auxiliary interfaces.

Mounting

Mounting steps

Detailed instructions for various mounting methods and considerations.

Electrical installation

Connections of the LMS1xx

Details the electrical connections for different LMS1xx variants.

Perform electrical installation on the LMS1xx

Guides on connecting interfaces, wiring system connectors, and M12 connectors.

Commissioning and configuration

SOPAS ET configuration software

Details the SOPAS ET software, its functions, and system requirements.

Establish communication with the LMS1xx

Instructions for establishing communication via Ethernet or RS-232.

Initial commissioning

Explains the process of adapting the LMS1xx to the local situation using SOPAS ET.

Connection and test measurement

Guides on verifying measurements and saving the final configuration.

Maintenance

Troubleshooting

In the event of faults or errors

Guidance on how to react when encountering malfunctions.

Error displays of the LEDs

Explains the meaning of LED indicators for error detection.

Indications of the 7-segment display

Details the information provided by the 7-segment display for diagnostics.

Detailed error analysis

Methods for detailed analysis of errors and malfunctions.

Technical specifications

Data sheet LMS1xx/LMC1xx laser measurement sensor