10 Programmable parameters
10.1 Incemental encoders
Parameter/Menu Item
DFS60B-xxPxxxxxx
DFS60B-xxMxxxxxx
DFS60A-xxPxxxxxx
DFS60A-xxMxxxxxx
DFV60A-22Pxxxxxx
DFS2xA-xxPxxxxxxxx
Description
Direction of rotation
(CW/ CCW / external)
Set rotation direction
X X X Absolute encoder:
Defines the direction of rotation as
viewed on the shaft.
CW = clockwise.
CCW = counter-clockwise.
External = setting via pin/wire.
Incremental encoder:
Enables the signal sequence to be
changed between A before B and B
before A.
TTL/HTL interface
Set electrical interface
X X X Defines the output interface for the
incremental signals.
Zero Set
Set zero pulse position
X X X Assigns the zero pulse to the current
shaft position.
Resolution
Set resolution
B: 1 to 10000
A: 1 to 65536
1 to 65536 Defines the number of pulses per
revolution.
Zero pulse width, electrical/mechan‐
ical
Set zero pulse width
X X X Defines the duration of the zero
pulse in relation to a signal period
(electrical) or a revolution (mechan‐
ical) of the encoder (type-depend‐
ent).
Device in delivery state
Reset to factory settings?
X X X Resets all parameters to the factory
settings of the encoder.