Technical Information Chapter 3
RFU63x
Mounting
8014335/YUO7/2016-04-04 © SICK AG · Germany · All rights reserved · Subject to change without notice 17
Technical Data
Radiation pattern diagram RFA630-000/-001
Type RFA630-000 RFA630-001
Part no. 1058383 1058384
Frequency band 860 MHz … 960 MHz
Carrier frequency 865 MHz … 868 MHz 902 MHz … 928 MHz
Permissible write/read device RFU630-13100 RFU630-13101
RFU630-13102
RFU630-13105
RFU630-13106/-13107
Maximum rated power
Max. 2 W ERP
1)
Max. 4 W EIRP
2)
Polarization
Circular /RHCP
3)
VSWR
4)
Typical < 1,2
Gain Max. 9 dBic
Axial ratio Typical < 2 dB
3 dB aperature angle Typical 72 Grad
Front to back ratio Typical > 17 dB
Electrical connection TNC reverse, 50 Ohm
Housing (material) Aluminum, Front: polycarbonate
Enclosure rating IP 67
Weight 3 kg
Dimensions (L x W x H) 238.6 mm x 238.6 mm x 64.3 mm, see dimensional drawing
Mounting 4 x M6 threaded mounting holes (standard fixing grid
40 mm x 40 mm) or 3 M5 threaded mounting holes
Operation ambient temperature –25 °C … +50 °C
Stockage temperature –30 °C … +70 °C
Relative air humidity 5 % … 95 %, non-condensing
1) ERP = Equivalent Radiated Power. 2) EIRP = Equivalent Isotropic Radiated Power.
3) RHCP = Right-Hand Circular Polarisation.
4) VSWR = Voltage Standing Wave Ration.
0°
15°
30°
45°
60°
75°
90°
105°
120°
135°
150°
165°
180°
–165°
–150°
–135°
–120°
–105°
–90°
–75°
–60°
–45°
–30°
–15°
–33
–30
–27
–24
–21
–18
–15
–12
–9
–6
–3
0
3
6
Elevation plane (vertical)
Azimuth plane (horizontal)
Measured gain in dBic at 866.5 MHz,
RHCP (Right-hand circular polarized)
9